SV-AS10EB, SV-AS10EG, SV-AS10GC, SV-AS10GN (serv.man2) - Panasonic Digital Camera Service Manual (repair manual). Page 14

Read Panasonic SV-AS10EB / SV-AS10EG / SV-AS10GC / SV-AS10GN (serv.man2) Service Manual online

Step 2.
Install of the CSP
SPOT HEATER
BOARD WAMER
Set the PCB to BOARD WARMER
The CSP has been aligned on the PCB.
Moving the PCB support plate, and then align the CSP 
repair area over the reflow hole.
NOTE: Pay attention to the hot air.
Preheat the PCB (at the CSP installation area) for applox. 
60 seconds.
CSP
PCB
Blower
Nozzle
Move the nozzle tip 
as close as possible 
to the CSP surface.
Shutter
PCB holder or
support plate
CAUTION: Be careful not to suffer a burn with the hot air from 
                  above and below.
Set the nozzle at the 
same position as set 
when the CSP was 
removed.
The nozzle position was 
adjusted when the CSP 
was removed.
*
Heat the PCB approx. 30 seconds.
Solder melts
When the solder melts, the CSP 
slightly moves or sinks due to a 
self alignment effect to correct 
subtle deviation.
*
Remove the PCB from the plate in applox. 30 seconds 
after closing the board wamer shutter.
applox. 30 seconds
  ----- A standard time necessary for the solder to become 
         solid on the PCB (cooling the PCB)
CSP install (repair) complete.      Confirm for deviation from the alignment 
                                                      marks again.
Install the capacitor and flash unit that have been removed.
This completes the repair of CSP. To check if the repair is successful or not, operate the 
circuit or perform some procedures such as the circuit checking procedure.