WV-CW240S, WV-CW244FE - Panasonic Video Monitoring Service Manual (repair manual). Page 10

Read Panasonic WV-CW240S / WV-CW244FE Service Manual online

2-4
PANASONIC REMOTE EVR ADJUSTMENT SYSTEM (C) MCI Co. CCTV PRODUCT:CW244EEPROM:0
✽   ✽   ✽   ✽   ✽   ✽   ✽  ✽   ✽  ✽   ✽  ✽  ✽   ✽   ✽   ✽   ✽   ✽  ✽  ✽  ✽  ✽  ✽ 
MENU
✽   ✽   ✽   ✽   ✽   ✽   ✽   ✽   ✽   ✽    ✽   ✽   ✽   
Page (1/1)
✽   ✽   ✽  ✽   ✽  
PAL
1. FSC ADJUSTMENT
3. ALC LEVEL
4. AGC OFF GAIN
5.1. OB LEVEL
5.2. VIDEO OUT GAIN
5.3. OB CONFIRM
6.1. BURST LEVEL 
6.2. BURST LEVEL 
6.3. BURST LEVEL 
6.4. BURST LEVEL 
7.1. 3200K R GAIN
7.2. 3200K B GAIN
7.3. 3200K PHASE
7.5. COLOUR CENTER POINT ADJUSTMENT
8.1. ATW CONFIRM
8.2. HI LIGHT CHROMA CLIP
<CONTENTS> CN1-2PIN [CCD] 14.18750 MHz + - 40 Hz
<INSTRUCTION> PLEASE CHOOSE MENU DATA BY ARROW-KEY
LOAD (F1)          QUIT (F3)             SAVE (F5)
Table 5-1
8
Press the SAVE (F5) key of the Computer, then the
Computer will ask you for the file name.
8
Type  xxxxxxxx.EVR. Give an appropriate file name for
xxxxxxxx within 8 letters, but do not use CW244E.
8
Press the ENTER key.
8
This saving procedure is recommended to keep the cur-
rent adjustment status of the Camera.
8
Press the LOAD (F1) key and type CW244E.EVR  and
press the ENTER key for presetting adjustment of the
Camera.
8
Press the ENTER key to start adjustment.
5.2. Adjustment Procedure-2 
(E.V.R. Adjustment) 
8
Insert new disk containing the E.V.R. Adjustment pro-
gram into IBM PC/AT and turn on the Power Switch of
IBM PC/AT.
8
When starting an adjustment, at the prompt, type LADJ
CW244E 
and press the ENTER key, an initial menu will
be displayed in Table 5-1.
300 mV 
±
 30 mV
(1). FSC  Adjustment
Test Point:
Pin 2 of CN1 (14MHz)
Sensor Board
8
Set the Synchronization Mode Selector (on the SW Board
SW1) to INT Position.
8
Connect the Frequency Counter to Pin 2 of CN1.
8
Adjust data with the ARROW keys so that the Subcurrier
Frequency becomes 14.18750 MHz ± 40 Hz.
8
Press the ENTER key for next adjustment.
(3). ALC Level Adjustment
Test Point:
Pin 1 of CN1 (CDS OUT)
Sensor Board
8
Keep the Colour Temperature at 3 200°K.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the Oscilloscope to the Pin 1 of CN1.
8
Adjust data with the ARROW keys so that the CDS OUT
signal level becomes 300 mV ± 30 mV as shown in Fig.
5-3.
Fig. 5-3
8
Press the ENTER key for next adjustment.
(4). AGC OFF Gain Adjustment
Test Point:
Pin 3 of CN1 (AGC OUT)
Sensor Board
8
Keep the Colour Temperature at 3 200°K.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the Oscilloscope to the Pin 3 of CN1.
8
Adjust data with the ARROW keys so that the AGC OUT
signal level becomes 300 mV ± 30 mV as shown in Fig.
5-4.
300 mV 
±
 30 mV
Fig.  5-4
8
Press the ENTER key for next adjustment.
Page of 44