WV-CW240S, WV-CW244FE - Panasonic Video Monitoring Service Manual (repair manual). Page 11

Read Panasonic WV-CW240S / WV-CW244FE Service Manual online

2-5
(5.1). OB Level Adjustment
Test Point:
Video Output Connector
8
Connect the terminated Oscilloscope with 75
to Video
Output Connector.
8
Adjust data with the ARROW keys so that the Pedestal
level becomes 50 mV ± 10 mV as shown in Fig. 5-5.
Fig. 5-5
8
Press the ENTER key for next adjustment.
(5.2). Video Output Gain Adjustment
Test Point:
Video Output Connector
8
Keep the Colour Temperature at 3 200°K.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the terminated Oscilloscope with 75
to Video
Output Connector.
8
Adjust data with the ARROW keys so that the Video sig-
nal level becomes 700 mV ± 50 mV as shown in Fig. 5-6.
700 mV 
±
 50 mV
50 mV 
±
 10 mV
Fig.  5-6
8
Press the ENTER key for next adjustment.
(5.3). OB Confirmation (Don't Change Data)
8
Press the ENTER key for next adjustment.
(6). Burst Level Adjustment
8
Repeat adjustment from steps (6.1) to  (6.4) until Burst
level, phase and Red vector phase are adjusted to proper
position as shown in Fig.5-7, 5-8, 5-9 and Table 5-2.
8
First, adjust the Burst Level and Phase according to fol-
lowing formula.
DATA of (6.1) = DATA of (6.3)
DATA of (6.2) = DATA of (6.4)
Note the DATA at each adjustment step.
8
Then adjust the Burst Level according to following formu-
la.
DATA of (6.1)
/
Current DATA – 
α
DATA of (6.2)
/
Current DATA + 
α
DATA of (6.3)
/
Current DATA – 
α
DATA of (6.4)
/
Current DATA + 
α
(6.1). Burst Level Adjustment
Test Point:
Video Output Connector
8
Keep the Colour Temperature at 3 200°K.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the terminated Oscilloscope with 75 
to Video
Output Connector.
8
Set the Mode Switch of the Vectorscope to NTSC mode.
8
Adjust data with the ARROW keys so that the Burst level
and phase are adjusted to proper position as shown in
Fig. 5-7 and Fig. 5-8.
8
Note the DATA for step (6.3).
8
Press the ENTER key for next adjustment.
(6.2). Burst Level Adjustment
Test Point:
Video Output Connector
8
Keep the Colour Temperature at 3 200°K.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the terminated Oscilloscope with 75 
to Video
Output Connector.
8
Adjust data with the ARROW keys so that the Burst level
and phase are adjusted to proper position as shown in
Fig. 5-7 and Fig. 5-8.
8
Note the DATA for step (6.4).
8
Press the ENTER key for next adjustment.
(6.3). Burst Level Adjustment
Test Point:
Video Output Connector
8
Keep the Colour Temperature at 3 200°K.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the terminated Oscilloscope with 75 
to Video
Output Connector.
8
Adjust data with the ARROW keys so that the data
becomes same value of adjustment step (6.1).
8
Press the ENTER key for next adjustment.
(6.4). Burst Level Adjustment
Test Point:
Video Output Connector
8
Keep the Colour Temperature at 3 200°K.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the terminated Oscilloscope with 75 
to Video
Output Connector.
Page of 44
Display

Click on the first or last page to see other WV-CW240S / WV-CW244FE service manuals if exist.