1-1
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
q w
e
r
t
!1
!0
o
i
u y
ON
12
3
OFF
ON
LL
SYNC
INT*
OFF*
BLC
ON
SOFT
AP
SHARP*
2nd transport protection screw (Red)
Space for heater unit
* Default setting
q
Focus lock lever
Fixes the focus position after adjusting.
w
Tilting lock screw
Fixes the tilting position after adjusting.
e
Zoom lock lever
Fixes the zoom position after adjusting.
r
Panning table
Adjusts the panning angle of the camera.
t
Azimuth adjuster
Adjusts the azimuth angle to obtain a level image.
y
Pan lock screw
Fixes the panning position after adjusting.
u
Video jack (3.5-diam. mini jack)
For connecting an LCD monitor to adjust the camera
images. Use an L-type plug to save space.
i
Aperture Level Selector
SHARP:
Sharpens the image outline.
SOFT:
Softens the image outline.
The default setting is SHARP.
o
Back Light Compensation Selector
ON:
Compensates the background if it is brighter than the
object.
OFF:
Does not compensate.
The default setting is OFF.
!0
Synchronization Mode Selector
Specifies a source for synchronization.
INT:
Internal 2:1 interlace.
LL:
Line-lock mode driven by 24 V AC or 220 V-240 V AC.
The default setting is INT.
Note:
Do not set the switch to LL (Line-Lock) position when
supplying 12 V DC to avoid synchronization error.
!1
Heater power connector
Supplies power to the optional heater unit when it is built in
the camera. Connect here a harness sticking out from the
heater unit.
Page of 44
Display