WV-CU950 - Panasonic Video Monitoring Service Manual (repair manual). Page 11

Read Panasonic WV-CU950 Service Manual online

1-6
4. Press the CAM (SET) button.
If the password entered is correct, all the settings will be
reset to the factory default.
5. Check “End” on the LCD.
Check “End” has appeared on the LCD to inform you of
the initialization end.
6. Turn off the power.
DIP SW SETTING
SW3 on the Ether Board do not make any Dip SW setting
other than Table-1. (Factory default setting)
ALL RESET
When the all reset mode is activated, all of the following set-
tings will be reset to the factory default.
• Administrator password
• PS·Data communication setting
• LCD brightness, contrast, alarm buzzer, and button
buzzer settings
• Button functions and joystick button functions (F1 to F8,
A, B, and top buttons)
• Controller functions
(Time & Date Type)
(Auto Login)
(Operator Setup)
(Function Level)
(Camera Level)
(Cam Posi Map)
(Cam-Unit Map)
(HDD-Unit Map)
(LCD Title)
Note: Calibration settings of panning, tilting, and zooming
will be maintained even after all reset.
3
Operation
1. Turn off the power.
Note: If you set the MODE Switch #1 to #5 to ON, you
can skip entering the administrator password in Step
3.
2. Turn on the power while holding down the buttons 2,
4, and 6.
“Enter Set Button” will appear on the LCD to enter the
CAM (SET) Button.
3. Enter the administrator password.
The password entered will be displayed as “
” marks.
Notes:
• The factory default is “650”.
• To delete a character, press the CLEAR button.
• If you have entered a wrong password, the LCD dis-
play will return to Step 2.
A l l   R e s e t
A l l   R e s e t
" E n t e r   S e t   B u t t o n "
A l l   R e s e t  
A d m i n   P a s s w o r d
∗∗∗∗∗
A l l   R e s e t
E n d
Ether Board
 
(Component side)
Table-1
SW3
1
ON
2
3
4
5
6
7
8
ON     OFF
Page of 59