WV-CS850, WV-CS854E - Panasonic Video Monitoring Service Manual (repair manual). Page 9

Read Panasonic WV-CS850 / WV-CS854E Service Manual online

– 6 –
3. Connection and Setting up for
Adjustment
3.1. Connection
8
Fig. 3-1 shows the connecting diagram for the adjustment
procedure of the WV-CS850/CS854E.
Fig. 3-1
8
Connect the Underscanned Colour Video Monitor to the
Video Output Connector of the E.V.R. Adjustment Kit
through the Waveform Monitor and the Vectorscope using
the coaxial cables.
8
Connect the Video Output Connector of the WV-CS850/
CS854E to the Camera Input Connector of the E.V.R.
Adjustment Kit by the coaxial cable.
8
Terminate the input terminal of the Underscanned Colour
Video Monitor with 75
.
8
For WV-CS854E, Connect the 24 V AC Power Supply
Unit.
8
Connect the +12 V DC Power Supply Unit to the E.V.R.
Adjustment Kit.
8
Connect the E.V.R. Adjustment Kit to IBM PC/AT type
using the Standard Straight RS-232C cable.
8
Connect the probe of the Digital Voltmeter, Oscilloscope
or Frequency Counter at the desired Test Point in each
adjustment step.
3.2. Setting Up for Remote E.V.R. Adjustment
Kit
< Remote E.V.R Adjustment Kit >
8
Fig. 3-2 shows the Remote E.V.R. Adjustment Kit.
Fig. 3-2
CAMERA
WV-CS850
WV-CS854E
E.V.R.
Adjustment Kit
Personal Computer
Standard
RS-232C
24 V AC
Power Supply
(for WV-CS854E)
220 – 240 V AC
(for WV-CS854E)
Floppy Disk
75 
Waveform
Monitor
Vector
Scope
Underscanned
Colour Video
Monitor
+ 12 V DC
Power Supply
< Switch Setting >
8
Referring to Fig. 3-3, remove four screws that secure the
Upper Cover and remove the Upper Cover.
Fig. 3-3
8
Set the switch SW3 on the board to the position as shown
in Fig. 3-4.
Fig. 3-4
8
Set the VP/STD CAMERA selection switch on the rear
panel according to the camera. 
8
Set to VP CAMERA position for VP Multiplexed Camera.
8
Set to STD CAMERA position for Standard Camera. 
< Menu Setting >
8
Set the Mode Selection Switch on the Front Panel to the
"ALARM OFF"(center) position.
8
Keep pressing the Program Switch for 3 seconds or more
until "Program Menu" is displayed on the monitor screen.
8
Move the cursor to the "Controller Set Up" position by
pressing the Up and Down Switch.
8
Display the "Controller Set Up Menu" on the monitor by
pressing the Set Switch.
8
Move the cursor to the "Set Up Disable" position by
pressing the Up and Down Switch.
8
Change "Disable" to "Enable" by pressing the Set Switch.
8
After completing the above setting, move the cursor to
the Communication position by pressing the Up and
Down Switch.
8
Display the "Communication Menu" on the monitor by
pressing the Set Switch.
8
After confirming the Baud Rate is 9600, finish this menu
by pressing the Program Switch twice.
<Rear>
<Fr
ont>
Board
SW3
ON
<SW3>
1
2
3
4
Select switch #2 to
ON position.
REMOTE
OPERATE
PROG
ALARM
RESET
NORMAL
SYSTEM
ALARM OFF
EVR
Left
Switch
Right
Switch
Mode Selection
Switch
Program
Switch
Up
Switch
Down
Switch
Set
Switch
IN
OUT
STD. CAMERA
VP CAMERA
VIDEO
CAMERA
DC12V IN
RS232C
VP/STD Camera Selection Switch
RS232C Connector
REMOTE
OPERATE
PROG
ALARM
RESET
NORMAL
SYSTEM
ALARM OFF
EVR
Remove four screws.
Upper Cover
Page of 43
Display