WV-CS850, WV-CS854E - Panasonic Video Monitoring Service Manual (repair manual). Page 5

Read Panasonic WV-CS850 / WV-CS854E Service Manual online

– 2 –
ADJUSTMENT PROCEDURE
1. Test Equipments Required
8
The following Test Equipments are required for
adjustment of the Combination Camera WV-CS850/
CS854E.
8
Oscilloscope
8
Frequency Counter
8
Digital Voltmeter
8
Vectorscope
8
Waveform Monitor
8
Underscanned Colour Video Monitor
8
12 V DC Power Supply Unit
8
Lux Meter
8
Lighting (275 footcandles (2,750 lux), Colour Temperature
3,200K)
8
Personal Computer (IBM PC/AT type or equivalent)
8
Standard Straight RS-232C Cable
8
White Chart or White Paper
8
Radiation Chart
8
Colour Temperature Conversion Filters as shown in Table
1-1.
Table 1-1
8
Logarithmic Gray Scale Chart (Part No.: YWV2310RB99).
8
Colour Chip Chart (Part No.: YWV2100RB98).
8
Electric Variable Resistor (E.V.R.) kit (Part No.:
YWV0EA1174AN) as shown in Fig. 1-1.
Fig. 1-1
8
Extension Cable for the Power Board and the Base Unit
(Part No.:V0EA1266AN) as shown in Fig. 1-2.
Fig. 1-2
8
Extension Board Ass'y (Part No.: V0EA1265AN) as shown
in Fig. 1-2.
(Break the small Boards from the Assembly Board.)
Fig. 1-2
8
Extension Cable 
A
for CN100 of the Main Board and the
Lens as shown in Fig. 1-3.
Fig. 1-3
8
Extension Cable 
B
for CN301 of the Main and CN9 of the
Servo Board as shown in Fig. 1-4.
Fig. 1-4
8
Extension Cable 
C
for CN5 of the Servo Board and the
Pan Motor as shown in Fig. 1-5.
Fig. 1-5
8
Extension Cable 
C
for CN6 of the Servo Board and the
Tilt Motor as shown in Fig. 1-6.
Fig. 1-6
8
Extension Cable 
D
for CN1 and CN2 of the
Communication Board and the Base Unit as shown in Fig.
1-7.
Fig. 1-7
Part No.                Description
KODAK
80B
change from 3,200 ˚K to 5,100 ˚K
KODAK
80B and 82C
change from 3,200 ˚K to 6,500 ˚K
D
C
C
B
A
CN100
CN301
CN9
CN5
CN6
CN1
CN2
Page of 43
Display