WV-CP460, WV-CP464 - Panasonic Video Monitoring Service Manual (repair manual). Page 4

Read Panasonic WV-CP460 / WV-CP464 Service Manual online

ADJUSTMENT PROCEDURE
1. Test Equipment Required
The following test equipment are required for adjustment
of  the Colour CCTV Camera WV-CP460 and WV-CP464.
Oscilloscope
Frequency Counter
Waveform Monitor
Vectorscope
Underscanned Colour Video Monitor
Video Signal Generator
12 V DC Power Supply Unit
Personal Computer (IBM PC/AT type or equivalent)
Standard Straight RS-232C Cable
ALC Lens (WV-LA9C3A, WV-LA9C3B or equivalent)
Lux Meter
Lighting (275 footcandles (2,750 ± 150 lux), Colour
Temperature 5,100 ± 100 K)
Colour Temperature Conversion Filters
(KENKO: W12, C4 or equivalent)
Radiation Chart
Logarithmic Gray Scale Chart. 
(Part Number:YWV2310RB99) 
Extension Cable as shown in Fig. 1-1.
(Part Number: YWV0EA1171AN) 
Make a conversion cable as follows.
Fig. 1-2
Remote Electric Variable Resistor (E. V. R.) kit as shown in
Fig. 1-2. (Part Number: YWV0EA1174AN) 
Fig. 1-3
13
12
11
10
9
8
7
6
5
4
3
2
1
26
25
24
23
22
21
20
19
18
17
16
15
14
GND
T (B)
R (B)
To
Remote
E. V. R.
Kit
To PC
Via RS-232C
Cable
2. Disassembling Procedure for
Adjustment
Referring to Fig. 2-1, remove two screws that secure the
Mount Adaptor and remove the Mount Adaptor.
Referring to Fig. 2-2, remove two screws that secure the
Main Cover and remove the Main Cover.
Remove two screws
Mount Adaptor
Fig. 2-1
Fig. 2-2
Remove two screws
Main Cover
– 2 –
WV-CP460 Series
Fig. 1-1
To 
Main Board 
CN404
To 
Power Board 
Unit CN101
CN3
CN2
Page of 25
Display