WV-CP240 - Panasonic Video Monitoring Service Manual (repair manual). Page 5

Read Panasonic WV-CP240 Service Manual online

– 3 –
8
Referring to Fig. 3-2, remove two screws that secure the
Front Shield Plate and remove the Front Shield Plate
from the Front Unit.
Fig. 3-2
Front Shield
Plate
4. Connection and Setting Up for
Adjustment
4.1. Connection
8
The Fig. 4-1 shows the connecting diagram for the Adjus-
tment Procedure.
Fig. 4-1
Test Chart
Lens
Floppy Disk
Vectorscope
12 V DC (for WV-CP242E)
24 V AC (for WV-CP244E)
220-240 V AC (for WV-CP240)
Underscanned
Colour Video
Monitor
12 V DC or 24 V AC
Power Supply Unit
E.V.R.
Adjustment
Kit
Cable for
E.V.R.
Adjustment
kit
12 V DC
Power Supply Unit
Printer
Connector
Personal 
Computer
75
CAMERA
8
Referring to Fig. 3-3, remove two screws that secure the
Sensor Board and remove the Sensor Board from the
Front Unit.
Fig. 3-3
Sensor
Board
Remove two screws
Front Unit
8
Remove the Optical Ass'y (IC1) from the Sensor Board.
Front Unit
Remove two screws
8
Connect the probe of the Digital Voltmeter, Oscilloscope
or Frequency Counter at the desired Test Point in each
adjustment step.
4.2. Setting Up for E.V.R. Adjustment Kit
<Connecting for E.V.R. Adjustment>
8
Referring to Fig. 4-1, connect the E. V. R. Adjustment kit
to CN2 on the Video Board of the Camera using the Cable
for E. V. R. Adjustment kit.
8
Connect the connector of the E. V. R. Adjustment Kit to
Personal Computer (IBM PC/AT type) using the printer
connector. 
8
Insert original floppy disk of E. V. R. Adjustment Kit to the
computer.
Page of 33
Display

Click on the first or last page to see other WV-CP240 service manuals if exist.