WJ-SX550 - Panasonic Video Monitoring Service Manual Supplement (repair manual). Page 16

Read Panasonic WJ-SX550 Service Manual Supplement online

– 14 –
7.2. Flow Chart for the CPU Board
7.2.1. Flow Chart for CPU Board alone Check
Start
Turn on the Power Switch
Set ”80(H)” by SW2 
Press CPU Reset Switch SW1 
Enter Idle mode and D4 blinking 
Set Test Mode No. by SW2
Press SW3 to start of Test
Press SW3 to enter Idle mode
SW2
MSB
LSB
ON
OFF
Test Result ?
MSB
LSB
NG
OK
Return to Idle?
Finish?
Turn off the Power Switch
End
Set ”0F(H)” by SW2 
1
    
2
    
3
    
4
    
5
    
6
    
7
    
8
SW2
MSB
LSB
ON
OFF
All LEDs should be off. 
D10  is  ON. 
YES
YES
NO
NO
D4 D5 D6 D7 D8 D9 D10 D11
D11  is  ON. 
MSB
LSB
D4 D5 D6 D7 D8 D9 D10 D11
MSB
LSB
D4 D5 D6 D7 D8 D9 D10 D11
1
    
2
    
3
    
4
    
5
    
6
    
7
    
8
SW2
MSB
LSB
ON
OFF
1
    
2
    
3
    
4
    
5
    
6
    
7
    
8
MSB
LSB
D4 D5 D6 D7 D8 D9 D10 D11
Note: It is possible to change from the Normal Operation Mode to the
          
  
Self Check mode or from the Self Check Mode to the Normal
          
 
Operation Mode when control is by the RS-485 line.
Page of 60
Display