WJ-NT104 - Panasonic Video Monitoring Service Manual (repair manual). Page 8

Read Panasonic WJ-NT104 Service Manual online

8
In case the Link Indicator on the Front Panel
does not light, the Network is incorrect.
Check the Network Condition.
8
In case the Receiving Indicator on the Front
Panel does not blink, the Network Cable has
problem. 
Check the Network Cable.
8
In case the Receiving Indicator and
Transmitting Indicator on the Front Panel do
not blink, the Network Setup of the PC is
incorrect. 
Check the PC Setup (IP
Address, Subnet Mask etc,.).
– 6 –
No Reply
8
In case the WJ-NT104 gives no reply as
shown in Table 7 and 8, the Network Setup
of the PC is incorrect. 
Check the PC
Setup (IP Address, Subnet Mask etc,.).
From page 4
Pinging XXX.XXX.XXX.XXX with 32 bytes of data:
Request timed out.
Request timed out.
Request timed out.
Request timed out.
Ping statistics for XXX.XXX.XXX.XXX
Packets: Sent = 4, Received = 0, Lost = 4 (100% loss),
Approximate round trip times in milli-seconds:
Minimum = 0ms, Maximum = 0ms, Average = 0ms
C:\nt104>_
Pinging XXX.XXX.XXX.XXX with 32 bytes of data:
Destination host unreachable.
Destination host unreachable.
Destination host unreachable.
Destination host unreachable.
Ping statistics for XXX.XXX.XXX.XXX
Packets: Sent = 4, Received = 0, Lost = 4 (100% loss),
Approximate round trip times in milli-seconds:
Minimum = 0ms, Maximum = 0ms, Average = 0ms
C:\nt104>_
Table 7
Table 8
Page of 38
Display