SAFETY PRECAUTIONS
GENERAL GUIDELINE
1. When service is required, observe the original lead dress.
   
Components, wires or cables that indicate evidence of
overheating or other electrical or mechanical damage
should be replaced.
2.
       
After servicing see to that all the protective devices, such
  as insulation tape, shields must be properly installed.
3. 
 
After servicing, make the following leakage current checks
to prevent the customer from being exposed to shock
  hazards.
LEAKAGE CURRENT COLD CHECK
1.
       
Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2.
       
Measure the resistance value, with an ohmmeter, between
     
the jumpered AC plug and each exposed metallic cabinet
 
             
part on the equipment such as screwheads, connectors,
         
control shafts, etc.
         
When the exposed metallic part has a return path to the
           
chassis, the reading should be between 1 M
  and 
           
5.2 M
. When the exposed metal does not have a return
path to the chassis, the reading must be 
  (infinity).
               
Any resistance value below  this range indicates an
abnormality which requires corrective action.
3.
       
Repeat the test with the AC switch in the "OFF" position.
LEAKAGE CURRENT HOT CHECK
1.
     
Plug the AC cord directly into adaptor socket and plug
 
           
adaptor into the AC outlet. Do not use an isolation
transformer for this check.
2.
         
Connect a 1.5 k
  / 10 W resistor, paralleled by 0.15 
µ
F
     
capacitor, between each exposed metallic part on the unit
    
and a good earth ground such as a water pipe, as shown
       
in Figure 1.
3.
     
Use an AC Voltmeter, with 1 k
 / Volt or more sensitivity,
to measure the potential across the resistor.
4.
     
Check all exposed metallic parts of the cover (BNC
    
connector, Handle bracket, Metallic cabinet, Screwheads,
Metallic overlays, etc.), and measure the voltage at each
       
point.
5.
       
Reverse the AC plug in the AC plug adaptor and repeat
        
each of the above measurements.
6. The potential at any point should not exceed 0.75 V RMS.
 
           
A leakage current tester (SIMPSON MODEL 229 or
 
        
equivalent) may be used to make the hot checks.
 
       
Leakage current must not exceed 0.5 milliampere.
       
In case a measurement is outside of the limits specified,
       
there is a possibility of a shock hazard, and corrective
         
action must be taken before returning the instrument to 
          
the customer.
AC  VOLTMETER
1.5 k
0.15 
µ
F
Water  Pipe
 (Earth  Ground)
Test  all  exposed
metal  parts
DEVICE
UNDER
TEST
AC  PLUG
ADAPTOR
AC  OUTLET
Ground  Lead    Disconnected during safety check.
Fig. 1   Leakage  Current  Hot  Check
PRODUCT COMPLIES WITH DHHS RULES 21 CFR SUBCHAPTER J 
APPLICABLE AT DATE OF MANUFACTURE
FOR WJ-HD200 (NTSC)