1. Safety Precautions 
  Read the following “SAFETY PRECAUTIONS” carefully before installation. 
  Electrical work must be installed by a licensed electrician. Be sure to use the correct rating and main circuit for 
the model to be installed. 
  The caution items stated here must be followed because these important contents are related to safety. The 
meaning of each indication used is as below. Incorrect installation due to ignoring of the instruction will cause 
harm or damage, and the seriousness is classified by the following indications. 
  Please leave this installation manual with the unit after installation. 
 
 
WARNING 
This indication shows the possibility of causing death or serious injury. 
 
CAUTION 
This indication shows the possibility of causing injury or damage to properties only. 
 
 
The items to be followed are classified by the symbols: 
 
 
Symbol with white background denotes item that is PROHIBITED from doing. 
 
Symbol with dark background denotes item that must be carried out. 
 
 
Carry out test run to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and 
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference. 
 
 
WARNING 
1. 
Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with 
other electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire. 
 
2.  Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen. 
 
3.  Keep plastic bag (packaging material) away from small children, it may cause suffocation. 
 
4.  Do not use pipe wrench to install refrigerant piping. It might deform the piping and cause the unit to malfunction. 
 
5.  Do not purchase unauthorized electrical parts for installation, service, maintenance and etc. They might cause electrical shock or fire. 
 
6. 
Do not modify the wiring of Indoor Unit for installation of other components (i.e. heater, etc). Overloaded wiring or wire connection 
points may cause electrical shock or fire. 
 
7.  Do not add or replace refrigerant other than specified type. It may cause product damage, burst and injury etc. 
 
8. 
Do not use joint cable for Indoor / Outdoor Unit connection cable. Use specified Indoor / Outdoor Unit connection cable, refer to 
instruction CONNECT THE CABLE TO THE INDOOR UNIT and connect tightly for Indoor / Outdoor Unit connection. Clamp the cable 
so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat up or fire at the 
connection. 
 
9. 
Do not install outdoor unit near handrail of veranda. When installing outdoor unit at veranda of high rise building, child may climb up to 
outdoor unit and cross over the handrail and causing accident. 
 
10.  Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury. 
 
 
11.  Do not sit or step on the unit, you may fall down accidentally. 
 
 
12. 
For electrical work, follow local wiring standard, regulation and this installation instruction. An independent circuit and single outlet 
must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 
 
13. 
For water circuit installation work, follow to relevant European and national regulations (including EN61770) and local plumbing and 
building regulation codes. 
 
14. 
Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or 
fire. 
 
15. 
 
This is a R410A model, when connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same may 
cause abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only R410A 
refrigerant. 
 
Thickness or copper pipes used with R410A must be 0.8 mm or more. Never use copper pipes thinner than 0.8 mm. 
 
It is desirable that the amount of residual oil is less than 40mg/10m. 
 
16. 
When install or relocate Indoor Unit / Outdoor Unit, do not let any substance other than the specified refrigerant, e.g. air etc. mix into 
refrigerant cycle (piping). Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc.. 
 
17.  Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock or fire. 
 
Page of 127