Read Panasonic WH-SXC09H3E5 / WH-SXC12H6E5 / WH-UX09HE5 / WH-UX12HE5 Service Manual online
7
2. Specifications
2.1 WH-SXC09H3E5
WH-UX09HE5
Item
Unit
Outdoor Unit
Performance Test Condition
EN 14511
Condition
(Ambient/Water)
A35W7
kW 7.00
BTU/h 23900
Cooling Capacity
kcal/h 6020
W/W 3.17
Cooling EER
kcal/hW 2.72
Condition
(Ambient/Water)
A7W35 A2W35
kW 9.00
9.00
BTU/h 30700
30700
Heating Capacity
kcal/h 7740
7740
W/W 4.84
3.59
Heating COP
kcal/hW 4.16
3.08
Low Temperature Application (W35)
Application Climate
Warmer Average Colder
Pdesign kW
9.0
9.0
11.0
Tbivalent / TOL
°C
2 / 2
-10 / -10
-15 / -22
SCOP / ns
(W/W) / %
5.95 / 235
4.59 / 181
4.08 / 160
Annual Consumption
kWh
2020
4049
6651
Class
A++ A++ A++
Medium Temperature Application (W55)
Application Climate
Warmer Average Colder
Pdesign kW
9.0
9.0
11.0
Tbivalent / TOL
°C
2 / 2
-10 / -10
-15 / -22
SCOP / ns
(W/W) / %
4.02 / 158
3.32 / 130
3.20 / 125
Annual Consumption
kWh
2991
5596
8468
Heating ErP
Class
A++ A++ A++
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
dB (A)
Cooling: 49
Heating: 51
—
Noise Level
Power Level dB
Cooling: 67
Heating: 68
—
Air Flow
m
3
/min (ft
3
/min)
Cooling: 89.5 (3160)
Heating: 76.8 (2710)
Heating: 76.8 (2710)
Refrigeration Control Device
Expansion Valve
Refrigeration Oil
cm
3
FV50S
(1200)
Refrigerant (R410A)
kg (oz)
2.85 (100.6)
GWP 2088
F-GAS
CO2eq (ton) (Precharged / Maximum)
5.951 / 8.039
Height
mm (inch)
1340 (52-3/4)
Width
mm (inch)
900 (35-7/16)
Dimension
Depth
mm (inch)
320 (12-19/32)
Net Weight
kg (lbs)
101 (223)
Liquid
mm (inch)
9.52 (3/8)
Pipe Diameter
Gas
mm (inch)
15.88 (5/8)
Standard Length
m (ft)
7 (23.0)
Pipe Length Range
m (ft)
3 (9.8) ~ 30 (98.4)
I/D & O/D Height Difference
m (ft)
20 (65.6)
Click on the first or last page to see other WH-SXC09H3E5 / WH-SXC12H6E5 / WH-UX09HE5 / WH-UX12HE5 service manuals if exist.