U-50PE2E5A, U-100PE1E8A, U-100PEY1E8, U-125PE1E8A, U-125PEY1E8, U-140PE1E8A, U-140PEY1E8, S-100PU2E5B, S-125PU2E5B, S-140PU2E5B, S-71PU2E5B, S-100PF1E5B, S-125PF1E5B, S-140PF1E5B, S-71PF1E5B - Panasonic Air Conditioner Service Manual (repair manual). Page 115

Read Panasonic U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B Service Manual online

1-1-4-23
1
1
Single -Type
1-1.  Unit Specifications
PE1
4. Low Silhouette Ducted Type S-71PF1E5B / U-71PE1E8A
INDOOR
MODEL
S-71PF1E5B
-
-
OUTDOOR
MODEL
-
U-71PE1E8A
-
Branch pipe
MODEL
-
Performance test condition
ISO13253  /  EN14511  /  EN14825  /   EN12102
Power supply
Ø, Hz
1ø 50Hz
3ø 50Hz
V
220
230
240
380
400
415
Min
Max
C
O
O
L
I
N
G
Capacity
kW
7.10
7.10
7.10
-
-
-
3.2
8.0
BTU/h
24200
24200
24200
-
-
-
10900
27300
Current
A
0.91
0.89
0.87
2.75
2.65
2.60
-
-
Input power
W
120
120
120
1.730k
1.730k
1.730k
-
-
TOTAL W
-
1.850k
1.850k
1.850k
640
2.650k
Annual consumption
TOTAL kWh *
4
-
-
925
-
-
-
EER/EER CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.84 / A
3.84 / A
3.84 / A
5.00
3.02
Erp
*
6
Pdesign
kW
-
-
-
-
7.1
-
-
-
SEER
(W/W)
-
-
-
-
6.0
-
-
-
Annual consumption
kWh
-
-
-
-
414
-
-
-
Class
-
-
-
-
A+
-
-
-
Power factor
%
-
-
-
96
94
93
-
-
Noise indoor
dB-A (H/M/L)
35/32/26
-
-
-
Power Level dB
57/54/48
-
-
-
Noise outdoor
dB-A (H/L)
-
48/-
-
-
Power Level dB
-
65/-
-
-
H
E
A
T
I
N
G
Capacity
kW
8.00
8.00
8.00
-
-
-
2.8
9.0
BTU/h
27300
27300
27300
-
-
-
9600
30700
Current
A
0.91
0.89
0.87
3.10
3.00
2.90
-
-
Input power
W
120
120
120
1.960k
1.960k
1.960k
-
-
TOTAL W
-
2.080k
2.080k
2.080k
580
2.900k
COP/COP CLASS
TOTAL (W/W) *
5
/ ("A"~"G")
-
-
-
3.85 / A
3.85 / A
3.85 / A
4.83
3.10
Erp
*
6
Pdesign at -10°C
kW
-
-
-
-
7.1
-
-
-
Tbivalent
°C
-
-
-
-
-9
-
-
-
SCOP
(W/W)
-
-
-
-
3.9
-
-
-
Annual consumption
kWh
-
-
-
-
2548
-
-
-
Class
-
-
-
-
A
-
-
-
Power factor
%
-
-
-
96
94
94
-
-
Noise indoor
dB-A (H/M/L)
35/32/26
-
-
-
Power Level dB
57/54/48
-
-
-
Noise outdoor
dB-A (H/L)
-
50/-
-
-
Power Level dB
-
67/-
-
-
EXTRA LOW TEMP Total capacity(kW) / Input power(W) / COP
-
-
Max Current(A) / Max Input power(W)
1.26/160
1.20/160
1.15/160
7.0/4.150k
7.0/4.360k
7.0/4.530k
-
Starting current(A) / Comp output(W)
-
-
-
3.10/2.0k
3.00/2.0k
2.90/2.0k
-
Network Impedance(ΩMAX.)
-
-
-
Fan motor output (Indoor/Outdoor) W
120
90
-
Moisture removal volume
L/h(Pt/h)
4.2
(8.8)
-
-
External static pressure
Pa
70 (MIN10 - MAX150)
-
-
Indoor  
Air flow 
Cooling
m³/min (ft³/min)
21.0/19.0/15.0 (742)/(671)/(530)
-
-
-
Heating
m³/min (ft³/min)
21.0/19.0/15.0 (742)/(671)/(530)
-
-
-
Outdoor  
Air flow
Cooling
m³/min (ft³/min)
-
60.0
(2119)
-
-
Heating
m³/min (ft³/min)
-
60.0
(2119)
-
-
Refrigerant type / amount g(oz)
-
R410A
2.35k
(82.9)
-
Product dimension
Height mm(inch)
290  (11-13/32)
996  (39-7/32)
-
Width
mm(inch)
1000  (39-3/8)
940  (37-1/32)
-
Depth
mm(inch)
700  (27-9/16)
340  (13-13/32)
-
Packing dimension
Height mm(inch)
355
1136
-
Width
mm(inch)
1214
1055
-
Depth
mm(inch)
850
485
-
Weight
(NET)
kg(lb)
33   (73)
71   (157)
-
(GROSS)  kg(lb)
41   (91)
79   (174)
-
Layers limit (actually)
9 (10) 
2 (3) 
-
Operation condition
Cool (DBT)
18°C ~ 32°C
-15°C ~ 46°C
-
Heat (DBT)
16°C ~ 30°C
-20°C ~ 24°C
-
P
I
P
I
N
G
Pipe diameter mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
-
Connecting method, Standard length m(ft)
flared type, 5.0(16.4)
flared type, 5.0(16.4)
-
Pipe length range     m (ft)
5 ~ 50m
(16.4 ~ 164.0)
-
Indoor unit & Outdoor unit height difference m (ft)
15m (OD located lower) / 30m (OD located higher)
(49.2/98.4)
-
Add gas amount g/m (oz/ft)
50g/m 
(0.538)
-
Pipe length for additional gas  m (ft)
30m
(98.4)
-
*1
: In case it is necessary to indicate the air flow volume in (l/s), the value in (m
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2
:  If the EUROVENT Certified models can be operated under the “extra-low” temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage 
230 V shall be used.
*3
: Network Impedance shall be applicable for EUROPE and CHINA models.
*4
: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5
: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6
:  SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season, 
Other fiche data indicates in an attached sheet.
SM830274-02_欧州向けR410Aシングル_TD&SM.indb   23
19/09/26   17:01:39
Page of 127
Display

Click on the first or last page to see other U-50PE2E5A / U-100PE1E8A / U-100PEY1E8 / U-125PE1E8A / U-125PEY1E8 / U-140PE1E8A / U-140PEY1E8 / S-100PU2E5B / S-125PU2E5B / S-140PU2E5B / S-71PU2E5B / S-100PF1E5B / S-125PF1E5B / S-140PF1E5B / S-71PF1E5B service manuals if exist.