S-22KA1E5, S-28KA1E5, S-36KA1E5, S-45KA1E5, S-56KA1E5, S-63KA1E5, S-71KA1E5, S-22YA1E5, S-28YA1E5, S-36YA1E5, S-45YA1E5, S-56YA1E5, S-22NA1E5, S-28NA1E5, S-32NA1E5, S-36NA1E5, S-45NA1E5, S-56NA1E5, S-45MA1E5, S-56MA1E5, S-63MA1E5, S-7 - Panasonic Air Conditioner Service Manual (repair manual). Page 14

Read Panasonic S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 Service Manual online

14 
Gas side 
mm (inch) 
12.70 (1/2) 
12.70 (1/2) 
12.70 (1/2) 
Diameter 
Liquid side 
mm (inch) 
6.35 (1/4) 
6.35 (1/4) 
6.35 (1/4) 
Piping 
Max Length 
m (ft) 
15.0 (49.20) 
15.0 (49.20) 
15.0 (49.20) 
External diameter 
mm 
16 
16 
16 
Drain hose 
Length mm 
650 
650 
650 
Fin material 
 
Aluminium (Pre Coat) 
Aluminium (Pre Coat) 
Aluminium (Pre Coat) 
Fin Type 
 
Slit Fin 
Slit Fin 
Slit Fin 
Row x Stage x FPI 
 
2 x 15 x 21 
2 x 15 x 21 
2 x 15 x 21 
Indoor Heat 
Exchanger 
Size (W x H x L) 
mm 
610.0 x 315.0 x 25.4 
610.0 x 315.0 x 25.4 
610.0 x 315.0 x 25.4 
Material  
Polypropylene 
Polypropylene 
Polypropylene 
Air Filter 
Type  
One-Touch 
One-Touch 
One-Touch 
Power Supply 
 
Indoor Power Supply 
Indoor Power Supply 
Indoor Power Supply 
Length m 
(ft) 
Power cord 
Core x Diameter 
mm
2
 -  - 
Thermostat 
 
Electronic Control 
Electronic Control 
Electronic Control 
Maximum °C 
32 
32 
32 
Cool 
Minimum °C 
21 
21 
21 
Maximum °C 
27 
27 
27 
Indoor Operation 
Range 
Heat 
Minimum °C 
16 
16 
16 
 
1. 
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air 
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb). 
2. 
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68.0°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F 
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb). 
3. 
Heating low temperature capacity, input power and COP measured at 230V, indoor temperature 20°C, outdoor 2/1°C. 
4. 
Heating extreme low temperature capacity, input power and COP measured at 230V, indoor temperature 20°C, outdoor -7/-8°C. 
5. 
Specifications are subjected to change without prior notice for future improvement. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other S-22KA1E5 / S-28KA1E5 / S-36KA1E5 / S-45KA1E5 / S-56KA1E5 / S-63KA1E5 / S-71KA1E5 / S-22YA1E5 / S-28YA1E5 / S-36YA1E5 / S-45YA1E5 / S-56YA1E5 / S-22NA1E5 / S-28NA1E5 / S-32NA1E5 / S-36NA1E5 / S-45NA1E5 / S-56NA1E5 / S-45MA1E5 / S-56MA1E5 / S-63MA1E5 / S-7 service manuals if exist.