9.5. Condensed Water Drainage.
This air conditioner employs a “Slinger-Up System” which is
designed to splash the condensed water on the condenser coil
for maximum cooling efficiency, thus producing a splashing
sound. If the splashing sound annoys you, you can provide an
outside drainage by using the following procedure which may,
however, cause a small loss of performance.
Note: If the unit is installed at coastal area, drainage of
condensed water is recommended to prevent the condenser
being corroded easily.
 1. Remove the rubber plug from the Base Pan.
 2. Slide out the Chassis from the Cabinet.
 3. Install the Drain Pan at the right or left corner of the Cabinet
with 2 screws.
     • 
• 
• 
• 
CW-C180EE & CW-C240EE.
     • 
• 
• 
• 
CW-A180EE.
 4. Connect the drain hose to the outlet of Drain Pan bottom.
 5. Slide the Chassis back into the Cabinet.
Note: Drain hose or tubing can be purchased locally to satisfy
your particular needs.