8.2.1. Parts Identification.
8.2.1.1. Vertical Airflow Direction Vane.
Airflow direction adjustment Up-and-Down.
•
•
•
•
The vertical airflow direction vane is
controlled by positioning the vane to
discharge the air upwards, downwards
or straight out.
controlled by positioning the vane to
discharge the air upwards, downwards
or straight out.
8.2.1.2. Ventilation Lever.
When the slide lever is in the:
•
•
•
•
“OPEN” position, the ventilation door
opens to allow air, smoke or odours to be
expelled from the room.
opens to allow air, smoke or odours to be
expelled from the room.
•
•
•
•
“CLOSE” position, the ventilation door is
closed and the air will be circulated inside
the room and conditioned.
closed and the air will be circulated inside
the room and conditioned.
8.2.1.3. Recommended.
Use the air conditioner under the following conditions:
•
•
•
•
Operating temperature range.
Indoor side
Outdoor side
D.B.T. W.B.T. D.B.T. W.B.T.
Cooling Maximum Temperature
32°C
23°C
43°C
26°C
Minimum Temperature
21°C
15°C
21°C
15°C
Heating Maximum Temperature
27°C
----
21°C
15°C
Minimum Temperature
20°C
----
-5°C
-6°C
D.B.T.: Dry Bulb Temperature
W.B.T.: Wet Bulb Temperature
Note: Humidity may exceed 90%.
−
−
−
−
Continuous operation at humidities of over 90% may
create condensation to form on the intake and outlet
vanes.
create condensation to form on the intake and outlet
vanes.
8.2. CW-A180EE (Cooling and Heating).