CW-C180EE, CW-C240EE, CW-A180EE - Panasonic Air Conditioner Service Manual (repair manual). Page 13

Read Panasonic CW-C180EE / CW-C240EE / CW-A180EE Service Manual online

8.2.1. Parts Identification.
8.2.1.1. Vertical Airflow Direction Vane.
Airflow direction adjustment Up-and-Down.
     • 
• 
• 
• 
The vertical airflow direction vane is
controlled by positioning the vane to
discharge the air upwards, downwards
or straight out.
8.2.1.2. Ventilation Lever.
When the slide lever is in the:
     • 
• 
• 
• 
“OPEN” position, the ventilation door
opens to allow air, smoke or odours to be
expelled from the room.
     • 
• 
• 
• 
“CLOSE” position, the ventilation door is
closed and the air will be circulated inside
the room and conditioned.
8.2.1.3. Recommended.
Use the air conditioner under the following conditions:
     • 
• 
• 
• 
Operating temperature range.
Indoor side
Outdoor side
D.B.T. W.B.T. D.B.T. W.B.T.
Cooling Maximum Temperature
32°C
23°C
43°C
26°C
Minimum Temperature
21°C
15°C
21°C
15°C
Heating Maximum Temperature
27°C
----
21°C
15°C
Minimum Temperature
20°C
----
-5°C
-6°C
D.B.T.: Dry Bulb Temperature
W.B.T.: Wet Bulb Temperature
Note: Humidity may exceed 90%.
     − 
− 
− 
− 
Continuous operation at humidities of over 90% may
create condensation to form on the intake and outlet
vanes.