CS-YE9MKX, CS-YE12MKX, CS-YE18MKX, CU-YE9MKX, CU-YE12MKX, CU-YE18MKX - Panasonic Air Conditioner Service Manual (repair manual). Page 6

Read Panasonic CS-YE9MKX / CS-YE12MKX / CS-YE18MKX / CU-YE9MKX / CU-YE12MKX / CU-YE18MKX Service Manual online

Lo m
3
/min (ft
3
/m) 
9.10 (321) 
10.84 (383) 
Me m
3
/min (ft
3
/m) 11.05(390) 
12.23 
(432) 
(HEATING) 
Hi m
3
/min (ft
3
/m) 
13.0 (459) 
13.9 (491) 
Hi  (Cooling) 
m
3
/min (ft
3
/m) 
33.0 (1165)  
34.5 (1218)  
Outdoor Airflow 
Hi  (Heating) 
m
3
/min (ft
3
/m) 
33.0 (1165) 
34.5 (1218) 
Control Device 
 
Capillary Tube 
Capillary Tube 
Refrigerant Oil 
cm
3
 
FV50S  (280) 
FV50S (320) 
Refrigeration 
Cycle 
Refrigerant Type  g (oz) 
R410A, 780 (27.6) 
R410A, 880 (31.1) 
Height(I/D / O/D) mm (inch) 
283 (11-15/32)
540 (21-1/4) 
283 (11-5/32) 540 
(21-1/4) 
Width (I/D / O/D) mm (inch) 
803 (31-5/8) 
780 (30-45/64)
803 (31-5/8) 780 
(30-45/64)
Dimension 
Depth (I/D / O/D) mm (inch) 
214 (8-7/16) 
289 (11-3/8) 
214 (8-7/16) 289 
(11-3/8) 
Weight 
Net (I/D / O/D) 
kg (lb) 
8.0 (18) 
22 (49) 
8.0 (18) 
26.5 (59) 
Pipe Diameter (Liquid / 
Gas) 
mm (inch) 
6.35 (1/4) / 9.52 (3/8) 
6.35 (1/4) / 9.52 (3/8) 
Standard length 
m (ft) 
7.5 (24.6) 
7.5 (24.6) 
Length range (min – max) m (ft) 
3 (9.8) ~ 15 (49.2) 
3 (9.8) ~ 15 (49.2) 
I/D & O/D Height different m (ft) 
5.0 (16.4) 
5.0 (16.4) 
Additional Gas Amount 
g/m (oz/ft) 
20  (0.2) 
20 (0.2) 
Piping 
Length for Additional Gas m (ft) 
7.5 (24.6) 
7.5 (24.6) 
Inner diameter 
mm 
16 
16 
Drain Hose 
Length mm 
500 
500 
Fin Material 
 
Pre coated 
Pre coated 
Fin Type 
 
Slit Fin 
Slit Fin 
Row x Stage x FPI 
 
2 x 16 x 19 
2 x 16 x 19 
Indoor 
Heat 
Exchanger 
Size (W x H x L) 
mm 
610 x 336 x 25.4 
610 x 336 x 25.4 
Fin Material 
 
Pre coated 
Pre coated 
Fin Type 
 
Slit Fin 
Slit Fin 
Row x Stage x FPI 
 
1 x 24 x 19 
2 x 24 x 17 
Outdoor 
Heat 
Exchanger 
Size (W x H x D) 
mm 
702.8 x 504 x 18.19           
702.8 x 504 x 18.19 
674.3 
Material 
 
P.P.HONEY COMB 
P.P.HONEY COMB 
Air Filter 
Type  
One-touch 
One-touch 
Power Supply 
 
Indoor 
Indoor 
Power Supply Cord 
16A 
16A 
Thermostat  
Protection Device 
 
 
COOLING HEATING COOLING HEATING 
TEMPERATURE (°C ) 
DB WB DB WB DB WB DB WB 
Maximum 
32 23 30  -  32 23 30  - 
Indoor Operation Range 
Minimum 
16 11 16  -  16 11 16  - 
Maximum 
43 26 24 18 43 26 24 18 
Outdoor Operation Range 
Minimum 
16 11 -5  -6 16 11 -5  -6 
 
1.  Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19°C Wet Bulb (66.2°F 
Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95.0°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb). 
2.  Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature 
of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb). 
3.  Specifications are subjected to change without prior notice for further improvement. 
 