Hi (COOLING) 
m
3
/min (ft
3
/m) 
36.0 (1271)  
Outdoor Airflow 
Hi (HEATING) 
m
3
/min (ft
3
/m) 
37.0 (1307)  
Control Device 
 
Expansion valve  
Refrigerant Oil 
cm
3
 
FV50S  (370)  
Refrigeration 
Cycle 
Refrigerant Type  g (oz) 
R410A, 1150 (40.5)  
Height(I/D / O/D) mm (inch) 
283 (11-5/32)  
540 (21-1/4)  
Width (I/D / O/D) mm (inch) 
803 (31-5/8)  
780 (30-45/64)  
Dimension 
 
Depth (I/D / O/D) mm (inch) 
214 (8-7/16)  
289 (11-3/8)  
Weight 
Net (I/D / O/D) 
kg (lb) 
7.5 (17)  
31.5 (70) 
Pipe Diameter (Liquid / 
Gas) 
mm (inch) 
6.35 (1/4) / 12.7 (1/2) . 
Standard length 
m (ft) 
7.5 (24.6)  
Length range (min – max) m (ft) 
3 (9.8) ~ 15 (49.2)  
I/D & O/D Height different m (ft) 
5.0 (16.4)  
Additional Gas Amount 
g/m (oz/ft) 
20  (0.2)  
Piping 
Length for Additional Gas m (ft) 
7.5 (24.6)  
Inner diameter 
mm 
16 
Drain Hose 
Length mm 
500 
Fin Material 
 
Pre coated  
Fin Type 
 
Slit Fin  
Row x Stage x FPI 
 
2 x 16 x 19 
Indoor 
Heat 
Exchanger 
Size (W x H x L) 
mm 
610 x 336 x 25.4 
Fin Material 
 
Pre coated  
Fin Type 
 
Slit Fin  
Row x Stage x FPI 
 
2 x 24 x 19 
Outdoor 
Heat 
Exchanger 
Size (W x H x D) 
mm 
702.8 x 504 x 18.19 
674.3 
Material 
 
P.P.HONEY COMB  
Air Filter 
Type  
One-touch 
 
Power Supply 
 
Indoor  
Power Supply Cord 
16A 
Thermostat  
Protection Device 
 
 
COOLING HEATING 
TEMPERATURE (°C ) 
DRY BULB 
WET BULB 
DRY BULB 
WET BULB 
Maximum 32 23 30  - 
Indoor Operation Range 
Minimum 16 11 16 - 
Maximum 43 26 24 18 
Outdoor Operation Range 
Minimum 16 11 -5 -6 
 
1.  Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19°C Wet Bulb (66.2°F 
Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95.0°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb). 
2.  Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature 
of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb). 
3.  Specifications are subjected to change without prior notice for further improvement. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 