Read Panasonic CS-YE9MKX / CS-YE12MKX / CS-YE18MKX / CU-YE9MKX / CU-YE12MKX / CU-YE18MKX Service Manual online
8
Hi (COOLING)
m
3
/min (ft
3
/m)
36.0 (1271)
Outdoor Airflow
Hi (HEATING)
m
3
/min (ft
3
/m)
37.0 (1307)
Control Device
Expansion valve
Refrigerant Oil
cm
3
FV50S (370)
Refrigeration
Cycle
Cycle
Refrigerant Type g (oz)
R410A, 1150 (40.5)
Height(I/D / O/D) mm (inch)
283 (11-5/32)
540 (21-1/4)
Width (I/D / O/D) mm (inch)
803 (31-5/8)
780 (30-45/64)
Dimension
Depth (I/D / O/D) mm (inch)
214 (8-7/16)
289 (11-3/8)
Weight
Net (I/D / O/D)
kg (lb)
7.5 (17)
31.5 (70)
Pipe Diameter (Liquid /
Gas)
Gas)
mm (inch)
6.35 (1/4) / 12.7 (1/2) .
Standard length
m (ft)
7.5 (24.6)
Length range (min – max) m (ft)
3 (9.8) ~ 15 (49.2)
I/D & O/D Height different m (ft)
5.0 (16.4)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
Piping
Length for Additional Gas m (ft)
7.5 (24.6)
Inner diameter
mm
16
Drain Hose
Length mm
500
Fin Material
Pre coated
Fin Type
Slit Fin
Row x Stage x FPI
2 x 16 x 19
Indoor
Heat
Exchanger
Heat
Exchanger
Size (W x H x L)
mm
610 x 336 x 25.4
Fin Material
Pre coated
Fin Type
Slit Fin
Row x Stage x FPI
2 x 24 x 19
Outdoor
Heat
Exchanger
Heat
Exchanger
Size (W x H x D)
mm
702.8 x 504 x 18.19
674.3
Material
P.P.HONEY COMB
Air Filter
Type
One-touch
Power Supply
Indoor
Power Supply Cord
A
16A
Thermostat
-
Protection Device
-
COOLING HEATING
TEMPERATURE (°C )
DRY BULB
WET BULB
DRY BULB
WET BULB
Maximum 32 23 30 -
Indoor Operation Range
Minimum 16 11 16 -
Maximum 43 26 24 18
Maximum 43 26 24 18
Outdoor Operation Range
Minimum 16 11 -5 -6
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19°C Wet Bulb (66.2°F
Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95.0°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature
of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3. Specifications are subjected to change without prior notice for further improvement.
Click on the first or last page to see other CS-YE9MKX / CS-YE12MKX / CS-YE18MKX / CU-YE9MKX / CU-YE12MKX / CU-YE18MKX service manuals if exist.