11.2.2.
Horizontal Airflow
1. Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the angles as
stated below. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Fig-
ure 1 below.
2. Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below and the posi-
tions of the vane are as Figure 2 above. 
11.3.
Quiet operation (Cooling Mode/Cooling area of Dry Mode)
A. Purpose
To provide quiet cooling operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
• When “quiet” button at remote control is pressed.
Quiet LED illuminates.
b. Quiet operation stop condition
1. When one of the following conditions is satisfied, quiet operation stops:
a. Powerful button is pressed.
b. Stop by OFF/ON switch.
c. Timer “off” activates.
d. Quiet button is pressed again.
Operation Mode
Vane Angle (
q)
Heating, with heat exchanger temperature
A
65 ~ 115
B
90
Cooling, Soft Dry and Ion
65 ~ 115
Pattern
1
2
3
4
5
Airflow Direction
Pattern at Remote
Control
Vane Angle (
q)
90
65
78
102
115