CS-XE9EKE, CU-XE9EKE, CS-XE12EKE, CU-XE12EKE - Panasonic Air Conditioner Service Manual (repair manual). Page 34

Read Panasonic CS-XE9EKE / CU-XE9EKE / CS-XE12EKE / CU-XE12EKE Service Manual online

34
(b) Soft Dry Operation
(c) Heating Operation
11.5.
ON Timer Control
ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time. This is to provide a
comfortable environment when reaching the set ON time.
60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to determine the
indoor intake air temperature and outdoor air temperature in order to judge the operation starting time.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
11.6.
OFF Timer Control
OFF timer can be set using remote control, the unit with timer set will stop operate at set time.
11.7.
Auto Restart Control
1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to four
minutes (there are 60 patterns of compressor restart waiting time between 2 minutes 58 seconds and 3 minutes 52 seconds
to be selected randomly) after power supply resumes. 
2. This type of control is not applicable during ON/OFF Timer setting.
11.8.
Remote Control Signal Receiving Sound
• Long beep sound will be heard when:-
- Stopping the air conditioner using ON/OFF switch.
• Short beep sound will be heard for others setting.
Page of 79