CS-XE9CKE, CU-XE9CKE, CS-XE12CKE, CU-XE12CKE - Panasonic Air Conditioner Service Manual (repair manual). Page 36

Read Panasonic CS-XE9CKE / CU-XE9CKE / CS-XE12CKE / CU-XE12CKE Service Manual online

Note:
 a. UP:
     • 
• 
• 
• If move from Lo, the fan speed will be shifted to Maximum 1160 rpm (XE9CK), 1330 rpm (XE12CK).
     • 
• 
• 
• If move from Maximum, the fan speed no change.
     • 
• 
• 
• In up zone, 10 rpm is added for every 10s until Maximum 1160 rpm (XE9CK), 1330 rpm (XE12CK).
 b. DOWN:
     • 
• 
• 
•  The fan speed will be decreased one step every 10 sec. until Minimum 840 rpm (XE9CK), 1100 rpm (XE12CK).
 c. Current Output Fixed:
     • 
• 
• 
• Maintain at present fan speed.
 d. Instantaneous Maximum:
     • 
• 
• 
• Fan speed will be increased to maximum auto fan speed.
8.2.3.2. Intake Air Temperature Control
Compressor will operate at maximum of 56 Hz (XE9CK), 69 Hz (XE12CK) respectively if either one of the below conditions occur:
 1. When the indoor intake air temperature is above 10°C and remote control setting fan speed is lower Me-.
 2. When the indoor intake air temperature is 30°C or above.
8.2.3.3. Outdoor Air Temperature Control
The compressor operating frequency is regulated in accordance to the outdoor air temperature as shown in the below figures. This
control will begin one minute after the compressor starts.
36
CS-XE9CKE CU-XE9CKE / CS-XE12CKE CU-XE12CKE
Page of 110
Display

Click on the first or last page to see other CS-XE9CKE / CU-XE9CKE / CS-XE12CKE / CU-XE12CKE service manuals if exist.