2. Specification 
2.1 CS-UE9JKE 
CU-UE9JKE 
 
Item 
Unit 
Indoor Unit 
Outdoor Unit 
kW 2.50(0.90~3.00) 
Capacity 
BTU/h 8530(3070~10230) 
W/W 3.33(4.73~3.00) 
EER 
BTU/hW 11.37(16.15~10.23) 
dB(A) 
Hi: 42 Lo: 27 QLo: 22 
Hi: 46 
COO
L
ING 
Noise Level 
Power level dB
53 
59 
kW 3.30(0.90~4.00) 
Capacity 
BTU/h 11260(3070~13650) 
W/W 3.66(4.09~3.33) 
COP 
BTU/hW 12.51(13.95~11.37) 
dB(A) 
Hi: 42 Lo: 27 QLo: 25 
Hi: 47 
HEATING 
Noise Level 
Power level dB
53 
60 
l/h 1.4 
Moisture Removal 
(pt/h) 2.4 
Lo m
3
/m (ft
3
/m)
6.15(232) 
Me m
3
/m (ft
3
/m)
7.93(300) 
Air Volume 
Hi m
3
/m (ft
3
/m)
10.08 (381) 
28.9(1020) 
Refrigerant Control Device  
Capillary 
Tube 
Refrigerant Oil (Charged) 
cm
3
 
RB68A or Freol Alpha68M 
Refrigerant (Charged) R410A 
kg (oz) 
0.78 (27.5) 
Height 
mm (inch) 
250 (9-27/32) 540 
(21-1/4) 
Width 
mm (inch) 
770 (30-5/16) 780 
(30-23/32) 
Dimension 
Depth 
mm (inch) 
205 (8-1/16) 289 
(11-3/8) 
Net Weight 
kg (lbs) 
7.0 
28 (62) 
Gas 
mm (inch) 
9.52 (3/8) 
Pipe 
Diameter 
Liquid 
mm (inch) 
6.35 (1/4) 
Pipe Length 
m (ft) 
3 (9.8) - 15(49.2) 
Height Difference 
m (ft) 
5 (16.4) 
Additional Gas Amount 
g/m (oz/ft) 
20 (0.2) 
Refrigerant Charge Less 
m (ft) 
7.5 (24.6) 
Inner diameter 
mm 
14 
Drain Hose 
Length mm  500 
Type   - 
Rotary 
Motor Type 
 
Induction (6-poles) 
Compressor 
Rated Output 
750 
Type 
 
Cross-Flow Fan 
Propeller Fan 
Material  
AS 
PP 
Motor Type 
 
Induction (8-poles) 
Induction (6-poles) 
Input power 
Output power 
30 
15 
Lo  
rpm 
830 
Me  
rpm 
1070 
Fan 
Fan 
Speed 
Hi  
rpm 
1360 
750 
Fin material 
 
Aluminium (Pre Coated) 
Aluminum ( Pre Coated) 
Fin type 
 
Slit Fin 
Slit Fin 
Row x stage x FPI 
 
2 x 12 x 18 
1 x 24 x 17 
Heat 
Exchanger 
Size (W x H x L) 
mm 
610 x 315 x 25.4 
709 x 504 x 18.2 
Material  
P.P.HONEY 
COMB 
Air Filter 
Type 
Style  
One-Touch 
 
1.  Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19°C Wet Bulb (66.2°F 
Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95.0°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb). 
2.  Heating capacities are based on indoor temperature of 20°C Dry Bulb (80.6°F Dry Bulb) and outdoor air 
temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb). 
 