1. Safety Precautions 
•  Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. 
•  Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the 
power plug and main circuit for the model installed. 
•  The caution items stated here must be followed because these important contents are related to safety. The 
meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction 
will cause harm or damage, and the seriousness is classified by the following indications. 
 
This indication shows the possibility of causing death or serious injury 
 
This indication shows the possibility of causing injury or damage to properties. 
•  The items to be followed are classified by the symbols: 
 
•  Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, 
care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for 
future reference. 
 
 
 
1. Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, 
electrical shock or fire. 
 
2.    Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical 
shock or fire. 
 
3.   Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water 
leakage, fire or electrical shock. 
 
4.    Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or 
installation is not properly done, the set will drop and cause injury. 
 
5.    Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise 
building, child may climb up to outdoor unit and cross over the handrail and causing accident. 
 
6.    For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent 
circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will 
cause electrical shock or fire. 
 
7.    This equipment is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual 
Current Device (RCD). Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulation 
breakdown. 
 
8.    This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning 
rod and telephone. Otherwise, it may cause electrical shock in case equipment breakdown or insulation breakdown. 
 
9.   Use the specified cable (1.5 mm
2
) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the 
cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up 
or fire at the connection. 
 
10. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed 
perfectly, it will cause fire or electrical shock. 
 
11.  When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into 
refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion 
and injury. 
 
12. Do not damage or use unspecified power supply cord. Otherwise, it will cause fire or electrical shock. 
 
13. Do not modify the length of the power supply cord or use extension cord, and do not share the single outlet with other 
electrical appliances. Otherwise, it will cause fire or electrical shock. 
 
14. • For R410A models, when connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same
may cause abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use 
only R410A materials. 
• Thickness or copper pipes used with R410A must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm
• It is desirable that the amount of residual oil is less than 40 mg/10 m. 
 
15. During installation, before run the compressor, confirm the refrigeration pipes are fixed. Operation of compressor 
without fixing the piping, setting the 2 way valve and 3-way valve at open condition, a burst may occur and cause 
injury. 
 
16. During pump down operation, stop the compressor before remove the refrigeration piping. When remove piping while 
2-way valve, 3 way valve at open condition, burst may occur and cause injury. 
 
Symbol with white background denotes item that is PROHIBITED from doing. 
  
   
 
Symbol with dark background denotes item that must be carried out. 
Page of 44