Order No: PHA-AG0903005C2 
 
 
 
Indoor Unit 
Outdoor Unit 
 
CS-UE9JKE 
CS-UE12JKE 
 
CU-UE9JKE 
CU-UE12JKE 
 
 
 
 
 
 
 
 
TABLE OF CONTENTS 
1.
 
Safety Precautions.............................................3
 
2.
 
Specification .......................................................5
 
2.1
 
CS-UE9JKE CU-UE9JKE ............................5
 
2.2
 
CS-UE12JKE CU-UE12JKE ........................7 
3.
 
Features ..............................................................9
 
4.
 
Location of Controls and Components .........10
 
4.1
 
Indoor Unit..................................................10
 
4.2
 
Outdoor Unit ...............................................10
 
4.3
 
Remote Control ..........................................10
 
5.
 
Dimensions .......................................................11
 
5.1
 
Indoor Unit..................................................11
 
5.2
 
Outdoor Unit ...............................................13
 
6.
 
Refrigeration Cycle Diagram...........................14
 
7.
 
Block Diagram ..................................................15
 
8.
 
Wiring Connection Diagram............................ 16 
8.1
 
CS-UE9JKE CU-UE9JKE ..........................18
 
8.2
 
CS-UE12JKE CU-UE12JKE ......................19
 
 
9.
 
Installation Instruction.....................................18
 
9.1
 
Select the Best Location ............................18
 
9.2
 
Indoor Unit..................................................19
 
9.3
 
Outdoor Unit ...............................................21
 
10.
 
Service Mode ....................................................24
 
10.1
 
Auto OFF/ON Button ..................................24
 
10.2
    
Select Remote Control Transmission Code24
 
10.3
 
Operate and Display of Remote Control ....25
 
11.
 
Operation Control.............................................27
 
11.1
 
Basic Function............................................27
 
11.2
 
Indoor Fan Motor Operation.......................28
 
11.3
 
Outdoor Fan Motor Operation ....................28
 
12.
 
Protection control ............................................31
 
 
 
This service information is designed for experienced repair technicians only and is not designed for use by the general public. 
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. 
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service 
or repair the products dealt with in this service information by anyone else could result in serious injury or death. 
WARNING
12.1
 
Protection Control For All Operations.........31
 
12.2
 
Protection Control For Cooling and Soft Dry 
Operation....................................................32
 
12.3
 
Outdoor Air Temperature Control...............33
 
13.
 
Troubleshooting Guide....................................35
 
13.1
 
Refrigeration Cycle System........................35 
13.2
 
Break Down self Diagnosis Function..........35 
14.
 
Disassembly and Assembly Instructions ......38
 
15.
 
Exploded View and Replacement Pars List...41
 
15.1
 
Indoor Unit ..................................................41
 
15.2
 
Outdoor Unit ...............................................43
 
 
 
CAUTION 
WARNING 
WARNING 
1. Safety Precautions 
•  Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. 
•  Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the 
power plug and main circuit for the model installed. 
•  The caution items stated here must be followed because these important contents are related to safety. The 
meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction 
will cause harm or damage, and the seriousness is classified by the following indications. 
 
This indication shows the possibility of causing death or serious injury 
 
This indication shows the possibility of causing injury or damage to properties. 
•  The items to be followed are classified by the symbols: 
 
•  Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, 
care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for 
future reference. 
 
 
 
1. Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, 
electrical shock or fire. 
 
2.    Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical 
shock or fire. 
 
3.   Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water 
leakage, fire or electrical shock. 
 
4.    Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or 
installation is not properly done, the set will drop and cause injury. 
 
5.    Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise 
building, child may climb up to outdoor unit and cross over the handrail and causing accident. 
 
6.    For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent 
circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will 
cause electrical shock or fire. 
 
7.    This equipment is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual 
Current Device (RCD). Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulation 
breakdown. 
 
8.    This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning 
rod and telephone. Otherwise, it may cause electrical shock in case equipment breakdown or insulation breakdown. 
 
9.   Use the specified cable (1.5 mm
2
) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the 
cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up 
or fire at the connection. 
 
10. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed 
perfectly, it will cause fire or electrical shock. 
 
11.  When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into 
refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion 
and injury. 
 
12. Do not damage or use unspecified power supply cord. Otherwise, it will cause fire or electrical shock. 
 
13. Do not modify the length of the power supply cord or use extension cord, and do not share the single outlet with other 
electrical appliances. Otherwise, it will cause fire or electrical shock. 
 
14. • For R410A models, when connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same
may cause abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use 
only R410A materials. 
• Thickness or copper pipes used with R410A must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm
• It is desirable that the amount of residual oil is less than 40 mg/10 m. 
 
15. During installation, before run the compressor, confirm the refrigeration pipes are fixed. Operation of compressor 
without fixing the piping, setting the 2 way valve and 3-way valve at open condition, a burst may occur and cause 
injury. 
 
16. During pump down operation, stop the compressor before remove the refrigeration piping. When remove piping while 
2-way valve, 3 way valve at open condition, burst may occur and cause injury. 
 
Symbol with white background denotes item that is PROHIBITED from doing. 
  
   
 
Symbol with dark background denotes item that must be carried out. 
CAUTION 
 
17. After completion of installation, confirm there is no leakage of refrigerant gas. It may generate toxic gas when the 
refrigerant contacts with fire. 
 
18. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when the refrigerant contacts with 
fire. 
 
19. Recommended installation height for indoor unit shall be at least 2.5 m. 
 
20. The appliance shall be installed in accordance with national wiring regulations. 
 
21. Keep away from small children, the thin film may cling to nose and mouth and prevent breathing. 
 
22. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury. 
 
23. Do not modify the machine, part, material during repairing service. 
 
24.  Must not use other parts except original parts describe in catalog and manual. 
 
 
 
 
1. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at 
surrounding of the unit, it may cause fire. 
 
2. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room 
and damage the furniture. 
 
3. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long 
period, the flare may break and cause refrigerant gas leakage. 
 
4. Do not touch outdoor unit air inlet and aluminums fin. It may cause injury. 
 
5.  Select an installation location which is easy for maintenance. 
 
6. Power supply connection to the air conditioner. 
Connect the power supply cord of the air conditioner to the mains using one of the following methods. 
Power supply point should be in easily accessible place for power disconnection in case of emergency. 
In some countries, permanent connection of this air conditioner to the power supply is prohibited. 
1) Power supply connection to the receptacle using a power plug. 
Use an approved 15/16A power plug with earth pin for the connection to the receptacle. 
2) Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for 
the permanent connection. It must be a double pole switch with a minimum 3.5 mm contact gap. 
 
7. Do not release refrigerant. 
Do not release refrigerant during piping work for installation, re-installation and during repairing a refrigeration parts. 
Take care of the liquid refrigerant, it may cause frostbite. 
 
8. Installation and service work. 
It may need two people to carry out the installation and service work. 
 
9.   Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
 
 
10. Do not sit ot step on the unit, you may fall down accidentally. 
 
11. Do not touch the sharp aluminium fin, sharp parts may cause injury. 
 
12. Thermal fuse specification for indoor unit: 250V 3.15A T3.15AL; outdoor unit: 205V 3.15A T3.15AL,205V 20A T20AL.
 
Page of 44
Display

Download Panasonic CS-UE9JKE / CS-UE12JKE / CU-UE9JKE / CU-UE12JKE Service Manual (Repair Manual)

Here you can read online and download Panasonic CS-UE9JKE / CS-UE12JKE / CU-UE9JKE / CU-UE12JKE Service Manual in PDF. CS-UE9JKE / CS-UE12JKE / CU-UE9JKE / CU-UE12JKE service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic CS-UE9JKE / CS-UE12JKE / CU-UE9JKE / CU-UE12JKE Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.