CS-UE7RKD, CS-UE9RKD, CS-UE12RKD, CS-UE18RKD, CU-UE7RKD, CU-UE9RKD, CU-UE12RKD, CU-UE18RKD - Panasonic Air Conditioner Service Manual (repair manual). Page 7

Read Panasonic CS-UE7RKD / CS-UE9RKD / CS-UE12RKD / CS-UE18RKD / CU-UE7RKD / CU-UE9RKD / CU-UE12RKD / CU-UE18RKD Service Manual online

Model 
Indoor 
CS-UE7RKD 
Outdoor 
CU-UE7RKD 
Piping 
Pipe Diameter (Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 9.52 (3/8) 
Standard length 
m (ft) 
5.0 (16.4) 
Length range (min – max) 
m (ft) 
3 (9.8) ~ 15 (49.2) 
I/D & O/D Height different 
m (ft) 
15.0 (49.2) 
Additional Gas Amount 
g/m (oz/ft) 
20 (0.2) 
Length for Additional Gas 
m (ft) 
7.5 (24.6) 
Drain Hose 
Inner Diameter 
mm  
16.7 
Length 
mm 
650 
Indoor Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Slit Fin 
Row × Stage × FPI 
 
2 × 15 × 17 
Size (W × H × L) 
mm 
610 × 315 × 25.4 
Outdoor 
Heat 
Exchanger 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Corrugated Fin 
Row × Stage × FPI 
 
1 × 20 × 19 
Size (W × H × L) 
mm 
22 × 508 × 708.4 
Air Filter 
Material 
 
Polypropelene 
Type 
 
One-touch 
Power Supply 
 
Outdoor 
Power Supply Cord 
Nil 
Thermostat 
 
Nil 
Protection Device 
 
Nil 
 
Dry Bulb 
Wet Bulb 
Indoor 
Operation 
Range 
Cooling 
Maximum °C 
32 
23 
Minimum °C 
16 
11 
Heating 
Maximum °C 
30 
– 
Minimum °C 
16 
– 
Outdoor 
Operation 
Range 
Cooling 
Maximum °C 
43 
26 
Minimum °C 
10 
– 
Heating 
Maximum °C 
24 
18 
Minimum °C 
-5 
-6 
 
1. 
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air 
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 
2. 
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb 
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) 
3. 
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor 2/1°C. 
4. 
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor -7/-8°C. 
5. 
Standby power consumption ≤ 2.0W (when switched OFF by remote control, except under self-protection control). 
6. 
Specifications are subjected to change without prior notice for further improvement. 
7. 
Maximum heating capacity shown are the values based on powerful operation. 
8. 
If the EUROVENT Certified models can be operated under the “extra-low” temperature condition, -7°C DB and -8°C WB temperature with 
rated voltage 230V shall be used. 
9. 
The annual consumption is calculated by multiplying the input power by an average of 500 hours per year in cooling mode. 
10.  SEER and SCOP classification is at 230V only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating 
season. Other fiche data indicates in an attached sheet. 
 
 
 
 
 
 
 
 
 
Page of 127