2. Specifications 
 
Model 
Indoor 
CS-UE7RKD 
Outdoor 
CU-UE7RKD 
Performance Test Condition 
JIS 
Power Supply 
Phase, Hz 
Single, 50 
220 
230 
 
Min. 
Mid. 
Max. 
Min. 
Mid. 
Max. 
Cooling 
Capacity 
kW 
0.75 
2.05 
2.40 
0.75 
2.05 
2.40 
BTU/h 
2560 
6990 
8180 
2560 
6990 
8180 
kcal/h 
650 
1760 
2060 
650 
1760 
2060 
Running Current 
– 
2.50 
– 
– 
2.40 
– 
Input Power 
255 
525 
640 
255 
525 
640 
Annual Consumption 
kWh 
– 
263 
– 
– 
263 
– 
EER 
W/W 
2.94 
3.90 
3.75 
2.94 
3.90 
3.75 
BTU/hW 
10.04 
13.31 
12.78 
10.04 
13.31 
12.78 
kcal/hW 
2.55 
3.35 
3.22 
2.55 
3.35 
3.22 
Power Factor 
– 
95 
– 
– 
95 
– 
Indoor Noise (H/L/QLo) 
dB-A 
39 / 25 / 22 
39 / 25 / 22 
Power Level dB 
55 / 41 / 38 
55 / 41 / 38 
Outdoor Noise 
dB-A 
46 
46 
Power Level dB 
61 
61 
Heating
 
Capacity 
kW 
0.75 
2.80 
3.60 
0.75 
2.80 
3.60 
BTU/h 
2560 
9550 
12300 
2560 
9550 
12300 
kcal/h 
650 
2410 
3100 
650 
2410 
3100 
Running Current 
– 
3.30 
– 
– 
3.20 
– 
Input Power 
245 
690 
1.07k 
245 
690 
1.07k 
COP 
W/W 
3.06 
4.06 
3.36 
3.06 
4.06 
3.36 
BTU/hW 
10.45 
13.84 
11.50 
10.45 
13.84 
11.50 
kcal/hW 
2.65 
3.49 
2.90 
2.65 
3.49 
2.90 
Power Factor 
– 
95 
– 
– 
94 
– 
Indoor Noise (H/L/QLo) 
dB-A 
39 / 25 / 23 
39 / 25 / 23 
Power Level dB 
55 / 41 / 39 
55 / 41 / 39 
Outdoor Noise 
dB-A 
47 
47 
Power Level dB 
62 
62 
Low Temp. : Capacity (kW) / I.Power (W) / COP 
2.61 / 950 / 2.75 
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 
2.20 / 960 / 2.29 
Max Current (A) / Max Input Power (W) 
4.9 / 1.07k 
Starting Current (A) 
3.30 
Compressor 
Type 
 
Hermetic Motor / Rotary 
Motor Type 
 
Brushless (6-poles) 
Output Power 
650 
 
 
 
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other CS-UE7RKD / CS-UE9RKD / CS-UE12RKD / CS-UE18RKD / CU-UE7RKD / CU-UE9RKD / CU-UE12RKD / CU-UE18RKD service manuals if exist.