2 Product Specifications
Unit
CS-PE9CKE
CU-PE9CKE
Cooling Capacity
kW
2.50(0.90-3.00)
Heating Capacity
kW
3.7
Moisture Removal
L/h
1.4
Power Source
Phase
V
Cycle
Single
230
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Circulation
Indoor air (low)
m
3
/min
6.1
Indoor air (medium)
m
3
/min
7.9
Indoor air (high)
m
3
/min
9.7
Outdoor air
m
3
/min
Noise Level
dB(A)
Cooling: High42, Low27
Cooling: High46
Heating: High42, Low27
Heating: High47
Electrical Data
Input
W
Cooling: 780(190-1000)
Heating: 910(170-1110)
Running Current
A
Cooling: 3.7
Heating: 4.0
EER
W/W
Cooling: 2.76
/COP
Heating:3.63
Starting Current
A
5.1
Piping Connection Port (Flare piping)
Inch
Inch
G: half union 3/8"
L: half union 1/4"
G: 3-way valve 3/8"
L: 2-way valve 1/4"
Piping Size
(Flare piping)
Inch
Inch
G: gas side 3/8"
L: liquid side 1/4"
G: gas side 3/8"
L: liquid side 1/4"
Drain
Hose
Inner diameter
mm
12
Length
m
0.6
Power Supply Cord Length (Number of core-wire)
m
2.2
3 core-wire/1.5mm
2

Dimensions
Height
mm
275
540
Width
mm
799
780
Depth
mm
210
289
Net Weight
kg
8.5
32
Compressor
Type
Rotary Type
Motor
Type
Brushless
Rated Output
W
650
5
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
Page of 84
Display