CS-PE9CKE, CU-PE9CKE, CS-PE12CKE, CU-PE12CKE - Panasonic Air Conditioner Service Manual (repair manual). Page 3

Read Panasonic CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE Service Manual online

Indoor Unit
Automatic Operation Switch
Press for <5s to run Automatic Operation.
(Used when the remote control cannot be
used.)
Press continuously for 5s and < 8s to run
Forced Cooling Operation.
Press continuously for 8s and <11s to run
Forced Heating Operation.
Press continuously for 11s and <16s to change
different remote controlling setting(A
B)
Mode.
Press continuously for 16s and < 21s to switch
OFF/ON Remote Control receiving Sound or
H14 Abnormality Detection Mode.
Operation Indication Lamps
Operation (green)
Timer(orange)
Iights up in operation
Blinks during Test
Run operation and
determining Auto
Operation mode
Timer in operation
Operation Mode
Heating/Cooling/Soft Dry Operation/
Auto Operation
Time Delay Safety Control
The unit will restart operation 3-4
minutes after each pause.
Auto Restart Control
Operation is restarted automatically at
previous mode after a power failure.
Anti-freezing Control for the Evaporator
Cooling or Soft Dry Operation
Supper Low , Low , Medium, High, Supper
High and Auto Fan Speed can be selected.
Deodorization
control is available for
cooling and soft dry operation.
Indoor Fan Speed Control
Automatic Airflow Direction Control
The louver automatically swings up and down
Airflow Direction Manual Control
Airflow Direction Control
Anti-fog Discharge Control
Cooling or Soft Dry Operation
AUTO
OFF/ON
3
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
Page of 84
Display

Click on the first or last page to see other CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE service manuals if exist.