Removal Procedure For Cross Flow Fan
Remote control reset
If the display is chaotic or can not be adjusted,
Remove the back lid of the remote control
and you will find the resetting terminals and
shorten the two terminals using a screw driver
to reset.
Resetting terminals
Fig 16
50
1.
(Fig. 12)
Release the two fixing screws,disassembly the fixing board from
evaporator on the left side of the evaporator and pull out the whole
evaporator.
2.Loose the fixing screw of the cross flow fan. (Fig. 13)
Fig. 12
Fig. 13
Fixing Screw
3.After removing the bearing (refer to fig14) , indoor fan can be
taken out from the left side.
Bearing
4. Lift up the indoor fan slightly, and then pull the fan motor out.
Fig15
Fig 15
Fan motor
Fig 14
CS-PC12DKD / CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
fixing board
Screw