CS-PC12DKD, CU-PC12DKD, CSCU-PA12DKD, CU-PA12DKD - Panasonic Air Conditioner Service Manual (repair manual). Page 47

Read Panasonic CS-PC12DKD / CU-PC12DKD / CSCU-PA12DKD / CU-PA12DKD Service Manual online

10.6. Gas charging
(After Evacuation)
(Indoor unit)
(Liquid side)
(Outdoor unit)
2-way
valve
(Gas side)
Open
3-way
valve
Open
Low
High
Open
Closed
Charging
cylinder
Procedure
1.Connect the charge hose to the charging cylinder.
2.Purge the air from the charge hose.
3 Open the valve (Low side) on the charge set and charge
the system with liquid refrigerant.
Connect the charge hose which was disconnected from
the vacuum pump to the valve at the bottom of the
cylinder.
If you are using a gas cylinder also use a scale and
reverse the cylinder so that the system can be charged
with liquid.
Open the valve at the bottom of the cylinder and use a
screwdriver to press the check valve on the charge set
to purge the air.(Be careful of the liquid refrigerant.)
The procedure is the same if using a gas cylinder.
.
If the system cannot be charged with the specified
amount of refrigerant, it can be charge with a little at a
time (approximately 150g each time) while operating the
air conditioner in the cooling cycle.
However, one time is not sufficient, wait approximately
1 minute and then repeat the procedure. ( Pumping
down pin )
4.Immediately disconnect the charge hose from the
3-way valve’s service port.
5.Mount the valve stem nuts and the service port.
Stopping part-way will allow the refrigerant to be
discharged.
If the system has been charged with liquid refrigerant
while operating the air conditioner, turn off the air
conditioner before disconnecting the hose.
Use a torque wrench to tighten the service port cap
to a torque of 1.8kgf.m (18 N.m)
Be sure to check for gas leakage.
47
This is different from previous procedures. Because you are
charging with liquid refrigerant from the gas side, absolutely
do no attempt to charge with large amount of liquid refrigerant
while operating the air conditioner.
CS-PC12DKD / CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
Page of 63
Display