CS-PC12DKD, CU-PC12DKD, CSCU-PA12DKD, CU-PA12DKD - Panasonic Air Conditioner Service Manual (repair manual)

cs-pc12dkd, cu-pc12dkd, cscu-pa12dkd, cu-pa12dkd service manual
Model
CS-PC12DKD CU-PC12DKD CSCU-PA12DKD CU-PA12DKD
Pages
63
Size
2.27 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-pc12dkd-cu-pc12dkd-cscu-pa12dkd-cu-pa12dkd.pdf
Date

Read Panasonic CS-PC12DKD / CU-PC12DKD / CSCU-PA12DKD / CU-PA12DKD Service Manual online

CS/CU-PC12DKD
CS/CU-PA12DKD
Air Conditioner
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-techical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service
or repair the product or products dealt with in this service information by anyone else could result in serious injury or death.
1 Features
2
2 Functions
3
3 Product Specifications
6
4 Dimensions
10
5 Refrigeration Cycle Diagram
12
6 Block Diagram
13
7 Wiring Diagram
15
8 Operation Details
17
9
Installation Insruction
31
10 2-way,3-way Valve
11
Disassembly of The Parts
12 Troubleshooting Guide
13 Technical Data
14 Exploded View
15 Replacement Parts List
16 Exploded View
17 Replacement Parts List
18 Electronic Circuit Diagram
CONTENTS
Page
Page
Order No. GMAC0504039C3
Guangzhou Matsushita Air Conditioner Co., Ltd.
C
R
41
48
51
53
55
56
57
58
59
------------------------------------------------------
--------------------------------------------------------
------------------------------------------
-----------------------------------------------------
-----------------------------------
--------------------------------------------------
-------------------------------------------------
-----------------------------------------------
---------------------------------------------------
-----------------------------------------------------
--------------------------------------
----------------------------------------
--------------------------------------------------
--------------------------------------------------
-----------------------------------------
--------------------------------------------------
-----------------------------------------
--------------------------------------
R
OFF
MODE
TEMP
OFF/ON
ON
CANCEL
SET
STD
TIMER
FAN
SPEED
AIR
SWING
2
1 Features
High Efficiency
Air Quality Indicator
Comfort Environment
Air filter with function to reduce dust and smoke
Auto Restart Control
Automatically restart after power failure
12-hour Timer Setting
CS-PC12DKD / CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
Operation START/STOP
Operation Mode Selection
Automatic
Operation
Heating Mode Operation
(For PA12DKD)
Cooling Mode Operation
Soft Dry Mode Operation
Air Circulation Mode Operation
(For PC12DKD)
Mode
Indoor Fan Speed Selection
Low Speed
Medium Speed
High Speed
Automatic Speed
Airflow Direction Control
Horizontal Airflow Direction Control
-Auto Control
-Manual Control
Vertical Airflow Direction Manual Control
Room Temperature Setting
Temperature Setting(16
to 30
)
Auto Operation
Timer Operation Selection
Stop/Start Operation Control
(set the ON/OFF Timer hourly later)
Set /Cancel Timer Operation
Set timer/Cancel the set timer
2
Functions
Remote Control
3
OFF/ON
MODE
FAN
SPEED
AIR
SWING
TEMP
TIMER
OFF/ON
TIMER
SET/
CANCEL
OFF
MODE
TEMP
OFF/ON
ON
CANCEL
SET
STD
TIMER
FAN SPEED
AIR SWING
Turn on/off the air conditionor
When stop the operation by pressing
OFF/ON button,the cursor key points
to OFF.
By pressing SET button for 5seconds
continuously to switch to set the sensor
sensitivity.
CS-PC12DKD / CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
Indoor Unit
Demonstration Mode
When the remote control cannot be used or
for repairing and testing ,please use this
button.
Power Switch ON/OFF
Signal Receiving Sound Control
Keep pressing this button for 10seconds to turn
on or turn off the signal receiving sound.
Operation Indication Lamps
Power (green)
Timer(orange)
Lights up in operation;
Blinks during Test
Run operation and
determining Auto
Operation mode
Timer in operation
Operation Mode
Cooling/Heating/Soft Dry /Auto Operation
/ Air circulation
Time Delay Safety Control
The unit will restart operation in 3-4
minutes after each pause.
7-Minutes Time Save Control
7-minutes automatic restarting at Cooling
Operation
National
4
Keep pressing this button for 15seconds to start
or end the Demonstration Mode.
Auto Switch
Button
Air quality
Green
Orange
Red
Anti-freezing Control for the Evaporator
Cooling or Soft Dry Operation
Warm Booting Control
Indoor fan starts running when temperature
of evaporator reaches 30
or above.
When temperature of evaporator is between
30
and 34
,indoor fan will run at Super Low
or Low speed.
When temperature of evaporator reaches 34
,
Warm Booting Operation ends.
High,Med,Low
Auto Fan Speed
Indoor Fan Speed Control
Automatic Airflow Direction Control
The louver automatically swings up and down
Airflow Direction Manual Control
Airflow Direction Control
Delayed On-timer Control
For cooling or soft dry mode, the unit
starts 15 minutes before the set time with
the remote control, but for heating mode
30 minutes before the set time.
CS-PC12DKD / CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
(For PA12DKD only)
Page of 63
Display

Download Panasonic CS-PC12DKD / CU-PC12DKD / CSCU-PA12DKD / CU-PA12DKD Service Manual (Repair Manual)

Here you can read online and download Panasonic CS-PC12DKD / CU-PC12DKD / CSCU-PA12DKD / CU-PA12DKD Service Manual in PDF. CS-PC12DKD / CU-PC12DKD / CSCU-PA12DKD / CU-PA12DKD service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic CS-PC12DKD / CU-PC12DKD / CSCU-PA12DKD / CU-PA12DKD Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.