CS-MA70KE, CS-MA90KE, CS-MA120KE, CU-MA180KE, CU-MA190KE, CU-MA240KE - Panasonic Air Conditioner Service Manual (repair manual). Page 9

Read Panasonic CS-MA70KE / CS-MA90KE / CS-MA120KE / CU-MA180KE / CU-MA190KE / CU-MA240KE Service Manual online

– 8  –
MAC9509078C2
CS-MA90KE
Heat
Exchanger
Refrigerant Control Device
Refrigeration Oil
Refrigeration (R-22)
Thermostat
Protection Device
Capillary Tube
Air Filter
Capacity Control
Compressor Capacitor
Fan Motor Capacitor
Description
Tube material
Fin material
Fin Type
Row / Stage
FPI
Size (W 
×
 H 
×
 L)
 µF, VAC
 µF, VAC
Length
Flow Rate
Inner Diameter
Material
Style
Unit
mm
(c.c)
g (oz)
mm
s
/min
mm
Product Specifications
CS-MA90KE
Evaporator
Copper
Aluminium
Slot Fin
×
 12
18
600 
×
 252 
×
 25.4
Electronic Control



P.P.
Honeycomb

(Plate fin configuration, forced draft)
Capillary Tube
• Specifications are subject to change without notice for further improvement.
CU-MA180KE
Condenser
Copper
Aluminium
Corrugated Fin
×
 18
19
856 
×
 457.2 
×
 22
Capillary Tube
SUNISO 4GDID or
ATMOS M60 (350 
×
 2)
850 
×
 2 (30.0 
×
 2)
Overload Protector
Cooling ; 1,033, Heating ; 585
Cooling ; 4.8, Heating ; 9.9
Cooling ; 1.2, Heating ; 1.4

25 µF, 370VAC
(Upper unit) 1.0 µF, 400VAC
(Lower unit) 1.2 µF, 400VAC
Untitled-4
6/30/00, 7:51 AM
8
Page of 56
Display