– 3 –
CS-A90KE
CS-MA90KE
MAC9509078C2
Indoor Unit
Functions
Power Switch OFF / ON
POWER
L
Auto Operation Switch
• Used when the remote control cannot be
used.
Remote Control Signal Receiving
Sound Control
Sound Control
• It can be controlled by pressing Auto
Operation Switch for 10 seconds.
AUTO
OFF / ON
Operation Test Running / Pump
Down Switch
Down Switch
TEST RUN
OFF / ON
Operation Indication Lamps (LED)
•
POWER
(Red)......
Lights up in operation,
blinks in Automatic
Operation Mode judging
and Hot Start operation
blinks in Automatic
Operation Mode judging
and Hot Start operation
•
SLEEP
(Orange).....
Lights up in Sleep
Mode Operation
Mode Operation
•
TIMER
(Orange).....
Lights up in Timer
Setting
Setting
• Used when test running or servicing.
Operation Mode
• Heating, Cooling, Soft Dry and Automatic
Mode.
Time Delay Safety Control
• Restarting is inhibited for appro. 3 or 4
minutes.
7 Minutes Time Save Control
• Cooling Operation only.
Auto Restart Control
• Operation is restarted after power failure
at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Sleep Mode Auto Control
• The operation starts at SLo speed and
stops after 8 hours.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
• Automatic Fan Speed Mode
– Heating : Fan speed varies from Me
→
SLo in accordance with
indoor heat exchanger.
– Cooling : Fan rotates at Hi and Me
speed. Deodorizing control is
available.
available.
– Soft Dry : Fan rotates at SLo speed.
Deodorizing control is
available.
available.
Airflow Direction Control
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal
airflow.
Hot-Start Control
• The indoor fan stops until the indoor heat
exchanger temperature over 30°C.
• The indoor fan operates at SLo and Lo
–
when indoor heat exchanger temperature
reaches 30°C ~ 41°C.
reaches 30°C ~ 41°C.
• Hot Start is completed when indoor heat
exchanger reaches 41°C.
Untitled-4
6/30/00, 7:51 AM
3