CS-MA70KE, CS-MA90KE, CS-MA120KE, CU-MA180KE, CU-MA190KE, CU-MA240KE - Panasonic Air Conditioner Service Manual (repair manual). Page 10

Read Panasonic CS-MA70KE / CS-MA90KE / CS-MA120KE / CU-MA180KE / CU-MA190KE / CU-MA240KE Service Manual online

– 9 –
CS-A90KE
CS-MA90KE
MAC9509078C2
Product Specifications
Inner diameter
Length
Input
Running Current
COP
Starting Current
Cooling Capacity
Heating Capacity
Moisture Removal
Power Source
Airflow Method
Air Volume
Noise Level
Electrical
Data
Piping Connection Port
(Flare piping)
Pipe Size
(Flare piping)
Drain
Hose
Power Cord Length
Number of core-wire
Dimensions
Net Weight
Compressor
Air Circulation
Height
Width
Depth
Type
Motor
Type
Rated
Output
Type
Material
Motor
Type
Input
Rated Output
Fan
Low
Speed
Medium
High
Unit
kW
Btu/h
kW
Btu/h
s
/h
Pint/h
Phase
V
Cycle
OUTLET
INTAKE
m
3
/min (cfm)
m
3
/min (cfm)
m
3
/min (cfm)
m
3
/min (cfm)
dB (A)
kW
A
W/W
A
inch
inch
inch
inch
mm
m
m
inch (mm)
inch (mm)
inch (mm)
lb (kg)
W
W
W
rpm
rpm
rpm
Indoor Air (Lo)
Indoor Air (Me)
Indoor Air (Hi)
Outdoor Air
CS-MA120KE
SIDE VIEW
Cooling ; 7.5 (260)
Heating ; 7.8 (280)
Cooling ; 8.4 (300)
Heating ; 8.7 (310)
Cooling ; 9.3 (330)
Heating ; 9.7 (340)
Cooling ; High 42-41, Low 38-37
Heating ; High 43-42, Low 38-37
G ; Half Union 1/2"
L ; Half Union 1/4"
G (gas side) ; 1/2"
L (liquid side) ; 1/4"
12
0.7
2.1
3 (1.0mm
2
)
11-7/16 (290)
31-15/32 (799)
6-29/32 (175)
18 (8.0)

Cross-flow Fan
AS + Glass Fiber 30%
Induction (4-poles)
20
1,210
1,350
1,500
3.50 
×
 2 - 3.45 
×
 2
11,900 
×
 2 - 11,800 
×
 2
4.10 
×
 2 - 4.00 
×
 2
14,000 
×
 2 - 13,600 
×
 2
2.0 
×
 2
4.2 
×
 2
Single
240 - 220
50
Cooling ; 1.25 
×
 2 - 1.22 
×
 2
Heating ; 1.28 
×
 2 - 1.23 
×
 2
Cooling ; 5.6 
×
 2 - 5.7 
×
 2
Heating ; 5.7 
×
 2 - 5.7 
×
 2
Cooling ; 2.8 - 2.8
Heating ; 3.2 - 3.3
25 
×
 2
CU-MA240KE
TOP VIEW
22.0 (780)
Cooling ; High 49-48 (52-51)
Heating ; High 49-48(52-51)
G ;  3-way valve 1/2"
L ; 2-way valve 1/4"
G (gas side) ; 1/2"
L (liquid side) ; 1/4"



41-5/32 (1045)
30-23/32 (780)
9-21/32 (245)
183 (83)
Rotary (1 cylinder)
rolling piston type
Induction (2-poles)
1,100 
×
 2
Propeller Fan
AES + Glass Fiber 12%
Induction (6-poles)
58.6 
×
 2
20 
×
 2

730
Untitled-4
6/30/00, 7:51 AM
9
Page of 56
Display