3 Product Specification
3.1.
CS-F14DB4E5 CU-B14DBE5
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
ELECTRICAL DATA (50 Hz)
ITEM / MODEL
Indoor Unit
Outdoor Unit
Main Body
CS-F14DB4E5
CU-B14DBE5
Panel
CZ-BT03P
Remote
Control
CZ-RD513C (Wired)
CZ-RL513B (Wireless)
Cooling Capacity
kW
3.8
BTU/h
13,000
Heating Capacity
kW
4.3
BTU/h
14,700
Refrigerant Charge-less
m
20
Standard Air Volume for High,
m
3
/min
15
54
cfm
530
1907
Outside Dimension (H x W x D)
mm
246 x 840 x 840
795 x 900 x 320
inch
9-11/16 x 33-1/24 x 33-1/24
31-5/16 x 35-7/16 x 12-19/32
Net Weight
kg (lbs)
25 (55)
55 (121)
Piping
Connection
Connection
Refrigerant
Gas
mm (inch)
O.D Ø 12.70 (1/2) Flared Type
Liquid
mm (inch)
O.D Ø 6.35 (1/4) Flared Type
Drain
mm
O.D Ø 20
I.D Ø 20
Compressor
Type, Number of Set
-
Hermatic, 1
Starting Method
-
Permanent Split Capacitor
Motor
Type
-
2-pole 1 phase brushless motor
Rated Output
kW
-
1.1
Fan
Type, Number of Set
Turbo fan-1
Mix flow fan,1
Motor
Type
8-pole DC motor
6-pole single phase induction motor
Rated Output
kW
0.04
0.07
Air-heat Exchanger (Row x Stage x FPI) Louver-fin type (1 x 8 x 21) Corrugate-fin type (1 x 36 x21)
Refrigerant Control
Refrigerant Control
-
Expansion Valve
Refrigerant Oil (Charged)
cm
3
-
FV50S (1130)
Refrigerant (Charged) R410a
kg (oz)
-
1.10 (38.8)
Running Adjust-
ment
Control Switch
Wireless or Wired Remote Control
-
Room Temperature
Thermostat
-
Noise Level
dB (A)
Cooling: 34/31
49/-
Heating: 34/31
50/-
Power Level
dB
Cooling: 49/46
65/-
Heating: 49/46
66/-
Moisture Removal
L/h (Pt/h)
2.2 (4.6)
EER
W/W
3.17/3.09/3.02
COP
W/W
3.61/3.52/3.44
ITEM / MODEL
Condition by ISO5151
Volts
V
220
230
240
Phase
Single
Single
Single
Power Consumption
kW
Cooling
1.20
1.23
1.26
Heating
1.19
1.22
1.25
Running Current
A
Cooling
5.5
5.5
5.5
Heating
5.45
5.45
5.45
Starting Current
A
23
24
25
Power Factor
%
Cooling
99
97
95
Heating
99
97
96
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic
Panasonic
Power source
AC, 1~220V, 230V, 240V 50Hz
Click on the first or last page to see other CS-F14DB4E5 / CU-B14DBE5 / CS-F18DB4E5 / CU-B18DBE5 service manuals if exist.