CS-F14DB4E5, CU-B14DBE5, CS-F18DB4E5, CU-B18DBE5 - Panasonic Air Conditioner Service Manual (repair manual). Page 11

Read Panasonic CS-F14DB4E5 / CU-B14DBE5 / CS-F18DB4E5 / CU-B18DBE5 Service Manual online

11
3.3.
Safety Devices
INDOOR UNIT
OUTDOOR UNIT
1Mpa=10.2kgf/cm2
Indoor Unit
Heat Pump Model
CS-F14DB4E5
CS-F18DB4E5
Cooling only Model
For fan motor current protection
Internal control board (note)
OFF
A
1.15
1.15
For control protection
Fuse
CUT
A
3.15
3.15
note: protection controlled by P.C.B installed of FM inside
Heat pump 
Model
50Hz
CU-B14DBE5
CU-B18DBE5
Outdoor Unit
For refrigerant cycle
High pressure
OFF
Mpa
4.15
4.15
switch (63H1)
ON
Mpa
3.05
3.05
For compressor
Over current protection
Heat pump model
OFF
A
8.5
12
RESET
Automatic
Automatic
Discharge temperature protection
Discharge temperature 
Compressor
thermistor (Th1)
OFF
°C
114
114
Liquid compress protection
Crankcase heater 
Input Power
W
37
37x2
Compressor protection
Internal protector 
OFF
°C 
50Hz
-
160
°C     
60Hz
ON
°C     
50Hz
-
90
°C     
60Hz
-
-
trip
50Hz
-
3-10sec/35A
time
60Hz
-
-
Compressor protection
OLP OFF
°C 
50Hz
145
-
°C     
60Hz
-
-
ON
°C     
50Hz
69
-
°C     
60Hz
-
-
trip
50Hz
6-16sec/23.5A
-
time
60Hz
-
-
For fan motor protection
Internal
OFF
°C
135
135
protector (49F)
ON
°C
85
85
Heating control (Heat Pump only)
Pressure switch
OFF
Mpa
_
_
(Fan speed) (63H2)
ON
Mpa
_
_
Cooling control
Heat exchanger outlet temperature
Control method
Th 40
°C ——— High speed
thermistor (Th2)
Th
40
°C ——— 5 speed step control
For control protection
Fuse
CUT
A
6.3
6.3
Page of 127