CS-E7GKDW, CU-E7GKD, CS-E9GKDW, CU-E9GKD, CS-E12GKDW, CU-E12GKD - Panasonic Air Conditioner Service Manual (repair manual). Page 9

Read Panasonic CS-E7GKDW / CU-E7GKD / CS-E9GKDW / CU-E9GKD / CS-E12GKDW / CU-E12GKD Service Manual online

9
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Blue Coat)
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2 x 15 x 21
2 x 24 x 17
Size (W x H x L)
mm
610 x 315 x 25.4
36.4 x 504 x 713
684
Air Filter
Material
Polypropelene
Type
One-Touch
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
220 - 230
Hz
50
Input Power
W
Cooling; 950 (185 ~ 1200)
Heating; 1280 (175 ~ 1910)
Starting Current
A
6.1
Running Current
A
Cooling; 4.6 - 4.4
Heating; 6.1 - 5.9
Power Factor
%
Cooling; 94 - 94
Heating; 95 - 94
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
A
8.8
Power Cord
Number of core
Length
m
Thermostat
Electronic Control
Protection Device
Electronic Control
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT
Page of 71
Display

Click on the first or last page to see other CS-E7GKDW / CU-E7GKD / CS-E9GKDW / CU-E9GKD / CS-E12GKDW / CU-E12GKD service manuals if exist.