7
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Blue Coat)
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2 x 15 x 19
2 x 24 x 17
Size (W x H x L)
mm
610 x 315 x 25.4
36.4 x 504 x 713
684
Air Filter
Material
Polypropelene
Type
One-Touch
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
220 - 230
Hz
50
Input Power
W
Cooling; 590 (175 ~ 750)
Heating; 835 (165 ~ 1340)
Starting Current
A
4.1
Running Current
A
Cooling; 3.0 - 2.8
Heating; 4.1 - 3.9
Power Factor
%
Cooling; 89 - 92
Heating; 93 - 93
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
A
5.9
Power Cord
Number of core
Length
m
Thermostat
Electronic Control
Protection Device
Electronic Control
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT