CS-E21JB4EA, CU-E21HBEA - Panasonic Air Conditioner Service Manual (repair manual). Page 68

Read Panasonic CS-E21JB4EA / CU-E21HBEA Service Manual online

68
15.5.21. F96 (IPM Overheating)
Malfunction Decision Conditions
During operating of cooling and heating, when IPM temperature data (100
°C) is detected by the IPM temperature sensor.
Multi Models Only
• Compressor Overheating: During operation of cooling and heating, when the compressor OL is activated.
• Heat Sink Overheating: During operation of cooling and heating, when heat sink temperature data (90°C) is detected by the heat
sink temperature sensor.
Malfunction Caused
• IPM overheats due to short circuit of hot discharge air flow.
• IPM overheats due to defective of outdoor fan motor.
• IPM overheats due to defective of internal circuitry of IPM.
• IPM overheats due to defective IPM temperature sensor.
Multi Models Only
• Compressor OL connector poor contact.
• Compressor OL faulty.
Troubleshooting
Page of 87
Display