Read Panasonic CS-E18JKDW / CU-E18JKD / CS-E21JKDW / CU-E21JKD / CS-XE18JKDW / CU-XE18JKD Service Manual online
8
MODEL
INDOOR
CS-E21JKDW
OUTDOOR
CU-E21JKD
Performance Test Condition
JIS
Power Supply
Phase, Hz
Single, 50
V
220
230
Min.
Mid.
Max.
Min.
Mid.
Max.
C
o
o
o
l
i
i
n
g
g
Capacity
kW
0.90
6.30
7.10
0.90
6.30
7.10
BTU/h
3070
21500
24200
3070
21500
24200
Kcal/h
770
5420
6110
770
5420
6110
Running Current
A
—
10.3
—
—
9.8
—
Input Power
W
215
2.21k
2.54k
215
2.21k
2.54k
Annual Consumption
kWh
—
1105
—
—
1105
—
EER
W/W
4.19
2.85
2.80
4.19
2.85
2.80
Kcal/hW
3.58
2.45
2.41
3.58
2.45
2.41
Power Factor
%
—
98
—
—
98
—
Indoor Noise (H / L / QLo)
dB-A
45 / 37 / 34
45 / 37 / 34
Power Level dB
61 / 53 / 50
61 / 53 / 50
Outdoor Noise (H / L)
dB-A
48 / -
48 / -
Power Level dB
62 / -
62 / -
H
e
a
a
t
i
i
n
g
g
Capacity
kW
0.90
7.20
8.50
0.90
7.20
8.50
BTU/h
3070
24600
29000
3070
24600
29000
Kcal/h
770
6190
7310
770
6190
7310
Running Current
A
—
9.7
—
—
9.3
—
Input Power
W
245
2.10k
2.75k
245
2.10k
2.75k
COP
W/W
3.67
3.43
3.09
3.67
3.43
3.09
Kcal/hW
3.14
2.95
2.66
3.14
2.95
2.66
Power Factor
%
—
98
—
—
98
—
Indoor Noise (H / L / QLo)
dB-A
45 / 37 / 34
45 / 37 / 34
Power Level dB
61 / 53 / 50
61 / 53 / 50
Outdoor Noise (H / L)
dB-A
49 / -
49 / -
Power Level dB
63 / -
63 / -
Low Temp.: Capacity (kW) / I.Power (W) / COP
6.16 / 2.43k / 2.53
Extr Low Temp.: Capacity (kW) / I.Power (W) / COP
5.24 / 2.54k / 2.06
Max Current (A) / Max Input Power (W)
12.1 / 2.75k
Starting Current (A)
10.3
Compressor
Type
Hermetic Motor
Motor Type
Brushless (4-poles)
Output Power
W
900
Click on the first or last page to see other CS-E18JKDW / CU-E18JKD / CS-E21JKDW / CU-E21JKD / CS-XE18JKDW / CU-XE18JKD service manuals if exist.