11
• Multi split Combination Possibility
- A single outdoor unit enables air conditioning of up to two separate rooms for CU-2E15GBE, CU-2E18CBPG.
- A single outdoor unit enables air conditioning of up to three separate rooms for CU-3E18EBE, CU-3E23CBPG.
- A single outdoor unit enables air conditioning of up to four separate rooms for CU-4E27CBPG.
- A single outdoor unit enables air conditioning of up to three separate rooms for CU-3E18EBE, CU-3E23CBPG.
- A single outdoor unit enables air conditioning of up to four separate rooms for CU-4E27CBPG.
Note: “ ”: Available
Remarks for CU-2E15GBE / CU-2E18CBPG
1. At least two indoor units must be connected.
2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable
2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable
capacity range of indoor unit. (as shown in the table above)
Example: The indoor unit’s combination below is possible to connect to CU-2E15GBE. (Total nominal capacity of indoor
units is between 4.4kW to 5.6kW)
Example: The indoor unit’s combination below is possible to connect to CU-2E15GBE. (Total nominal capacity of indoor
units is between 4.4kW to 5.6kW)
a. Two CS-E7JKDW only. (Total nominal cooling capacity is 4.4kW)
b. One CS-E7JKDW and one CS-E9JKDW. (Total nominal cooling capacity is 5.0kW)
b. One CS-E7JKDW and one CS-E9JKDW. (Total nominal cooling capacity is 5.0kW)
Remarks for CU-3E18EBE / CU-3E23CBPG / CU-4E27CBPG
1. At least two indoor units must be connected.
2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable
2. The total nominal cooling capacity of indoor units that will be connected to outdoor unit must be within connectable
capacity range of indoor unit. (as shown in the table above)
Example: The indoor unit’s combination below is possible to connect to CU-3E23CBPG. (Total nominal capacity of indoor
units is between 5.0kW to 10.0kW)
Example: The indoor unit’s combination below is possible to connect to CU-3E23CBPG. (Total nominal capacity of indoor
units is between 5.0kW to 10.0kW)
a. Two CS-E9JKDW only. (Total nominal cooling capacity is 5.6kW)
b. Three CS-E12JKDW. (Total nominal cooling capacity is 9.6kW)
b. Three CS-E12JKDW. (Total nominal cooling capacity is 9.6kW)
Outdoor Unit
CU-2E15GBE CU-2E18CBPG
CU-3E18EBE
CU-3E23CBPG
CU-4E27CBPG
A
B
A
B
A
B
C
A
B
C
A
B
C
D
W
A
L
L
L
2.2 kW CS-E7JKEW
CS-E7JKDW
2.8 kW CS-E9JKEW
CS-E9JKDW
3.2 kW CS-E12JKEW
CS-E12JKDW
4.0 kW CS-E15JKEW
CS-E15JKDW
—
—
—
—
5.0 kW CS-E18JKEW
CS-E18JKDW
—
—
—
—
Capacity range of
connectable indoor
units
connectable indoor
units
From 4.4kW to 5.6kW
From 4.4kW to 6.4kW
From 5.0kW to 9.0kW
From 5.0kW to 10kW
From 5.0kW to 13.6kW
P
I
P
I
N
G
G
L
E
N
N
G
T
H
1 room
maximum pipe
length (m)
20
20
25
25
25
Allowable
elevation (m)
10
10
15
15
15
Total
allowable pipe
length (m)
30
30
50
50
70
Total pipe
length for
maximum
chargeless
length (m)
20
20
30
30
40
Additional gas
amount over
chargeless
length (m)
20
20
20
20
20