CS-E18JKDW, CU-E18JKD, CS-E21JKDW, CU-E21JKD, CS-XE18JKDW, CU-XE18JKD - Panasonic Air Conditioner Service Manual (repair manual). Page 7

Read Panasonic CS-E18JKDW / CU-E18JKD / CS-E21JKDW / CU-E21JKD / CS-XE18JKDW / CU-XE18JKD Service Manual online

7
1. Cooling capacities are based on indoor temperature of 27
qC Dry Bulb (80.6qF Dry Bulb), 19.0qC Wet Bulb (66.2qF Wet Bulb)
and outdoor air temperature of 35
qC Dry Bulb (95qF Dry Bulb), 24qC Wet Bulb (75.2qF Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
qC Dry Bulb (68qF Dry Bulb) and outdoor air temperature of 7qC Dry
Bulb (44.6
qF Dry Bulb), 6qC Wet Bulb (42.8qF Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20
qC, outdoor 2/1qC.
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20
qC, outdoor
-7/-8
qC.
5. Specifications are subjected to change without prior notice for further improvement.
 MODEL
INDOOR
CS-E18JKDW  CS-XE18JKDW
OUTDOOR
CU-E18JKD  CU-XE18JKD
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row 
u Stage u FPI
u 15 u 19
Size (W 
u H u L)
mm
810 
u 315 u 25.4
Outdoor Heat
Exchanger
Fin Material
Aluminium (Blue Coat)
Fin Type
Corrugated Fin
Row 
u Stage u FPI
u 34 u 17
Size (W 
u H u L)
mm
36.4 
u 714 u 794
                     823
Air Filter
Material
Polypropylene
Type
One-Touch
Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic Control
Protection Device
Electronic Control
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
Minimum
16
11
Heating
Maximum
30
Minimum
16
Outdoor Operation Range
Cooling
Maximum
43
26
Minimum
16
11
Heating
Maximum
24
18
Minimum
-5
-6