CS-E18GKDW, CU-E18GKD, CS-E21GKDS, CU-E21GKD - Panasonic Air Conditioner Service Manual (repair manual). Page 12

Read Panasonic CS-E18GKDW / CU-E18GKD / CS-E21GKDS / CU-E21GKD Service Manual online

12
6 Refrigeration Cycle Diagram
If piping length is over common length, additional refrigerant should be added as shown in the table.
Model
Piping size
Rated
Length
(m)
Common
Length
(m)
Max.
Elevation
(m)
Min. Piping
Length
(m)
Max. Piping
Length
(m)
Additional
Refrigerant
(g/m)
Gas
Liquid
E18GK, E21GK
1/2”
1/4”
5
10
15
3
20
20