Read Panasonic CS-E18GKDW / CU-E18GKD / CS-E21GKDS / CU-E21GKD Service Manual online
Order No. MAC0701012C2
Air Conditioner
CS-E18GKDW CU-E18GKD
CS-E21GKDS CU-E21GKD
TABLE OF CONTENTS
PAGE
PAGE
1 Safety Precautions----------------------------------------------- 2
2 Specifications ----------------------------------------------------- 4
2 Specifications ----------------------------------------------------- 4
2.1. CS-E18GKDW CU-E18GKD--------------------------- 4
2.2. CS-E21GKDS CU-E21GKD --------------------------- 6
2.2. CS-E21GKDS CU-E21GKD --------------------------- 6
3 Features ------------------------------------------------------------- 8
4 Location of Controls and Components ------------------- 9
4 Location of Controls and Components ------------------- 9
4.1. Indoor Unit--------------------------------------------------- 9
4.2. Outdoor Unit ------------------------------------------------ 9
4.3. Remote Control -------------------------------------------- 9
4.2. Outdoor Unit ------------------------------------------------ 9
4.3. Remote Control -------------------------------------------- 9
5 Dimensions--------------------------------------------------------10
5.1. Indoor Unit & Remote Control -------------------------10
5.2. Outdoor Unit ----------------------------------------------- 11
5.2. Outdoor Unit ----------------------------------------------- 11
6 Refrigeration Cycle Diagram --------------------------------12
7 Block Diagram----------------------------------------------------13
8 Wiring Connection Diagram ---------------------------------14
9 Electronic Circuit Diagram -----------------------------------15
7 Block Diagram----------------------------------------------------13
8 Wiring Connection Diagram ---------------------------------14
9 Electronic Circuit Diagram -----------------------------------15
9.1. Indoor Unit--------------------------------------------------15
9.2. Outdoor Unit----------------------------------------------- 16
10 Printed Circuit Board ------------------------------------------ 17
10.1. Indoor Unit ------------------------------------------------- 17
10.2. Indicator ---------------------------------------------------- 18
10.3. Outdoor Unit----------------------------------------------- 19
10.2. Indicator ---------------------------------------------------- 18
10.3. Outdoor Unit----------------------------------------------- 19
11 Installation Instruction ---------------------------------------- 20
11.1. Select The Best Location ------------------------------ 20
11.2. Indoor/Outdoor Unit Installation Diagram ---------- 20
11.3. Indoor Unit ------------------------------------------------- 21
11.4. Outdoor Unit----------------------------------------------- 24
11.2. Indoor/Outdoor Unit Installation Diagram ---------- 20
11.3. Indoor Unit ------------------------------------------------- 21
11.4. Outdoor Unit----------------------------------------------- 24
12 Operation And Function -------------------------------------- 27
12.1. Basic Function -------------------------------------------- 27
12.2. Airflow Direction ------------------------------------------ 27
12.3. Quiet operation (Cooling Mode/Cooling area
12.2. Airflow Direction ------------------------------------------ 27
12.3. Quiet operation (Cooling Mode/Cooling area
of Soft Dry Mode) ---------------------------------------- 28
12.4. Powerful Mode Operation------------------------------ 30
12.5. ON Timer Control ---------------------------------------- 30
12.5. ON Timer Control ---------------------------------------- 30
2
12.6. OFF Timer Control --------------------------------------- 31
12.7. Auto Restart Control------------------------------------- 31
12.8. Indication Panel------------------------------------------- 31
12.9. Patrol Operation ------------------------------------------ 31
12.7. Auto Restart Control------------------------------------- 31
12.8. Indication Panel------------------------------------------- 31
12.9. Patrol Operation ------------------------------------------ 31
12.10. e-ion Operation ------------------------------------------- 33
13 Protection Control ---------------------------------------------- 36
13.1. Protection Control For All Operations --------------- 36
13.2. Protection Control For Cooling & Soft Dry
13.2. Protection Control For Cooling & Soft Dry
Operation--------------------------------------------------- 37
13.3. Protection Control For Heating Operation --------- 38
14 Servicing Mode -------------------------------------------------- 40
14.1. Auto OFF/ON Button ------------------------------------ 40
14.2. Select Remote Control Transmission Code ------- 40
14.3. Remote Control Button --------------------------------- 41
14.2. Select Remote Control Transmission Code ------- 40
14.3. Remote Control Button --------------------------------- 41
15 Troubleshooting Guide---------------------------------------- 42
15.1. Refrigeration Cycle System --------------------------- 42
15.2. Relationship Between The Condition Of The
Air Conditioner And Pressure And Electric
Current ----------------------------------------------------- 43
Current ----------------------------------------------------- 43
15.3. Breakdown Self Diagnosis Function ---------------- 44
15.4. Error Codes Table --------------------------------------- 45
15.4. Error Codes Table --------------------------------------- 45
16 Disassembly and Assembly Instructions -------------- 46
16.1. Indoor Electronic Controllers, Cross Flow Fan
And Indoor Fan Motor Removal Procedures ----- 46
16.2. Outdoor Electronic Controller Removal
Procedure-------------------------------------------------- 50
17 Technical Data --------------------------------------------------- 51
17.1. Operation Characteristics ----------------------------- 51
17.2. Sensible Capacity Chart ------------------------------- 59
17.2. Sensible Capacity Chart ------------------------------- 59
18 Exploded View and Replacement Parts List----------- 60
18.1. CS-E18GKDW CS-E21GKDS ----------------------- 60
18.2. CU-E18GKD CU-E21GKD --------------------------- 62
18.2. CU-E18GKD CU-E21GKD --------------------------- 62
1 Safety Precautions
• Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.
• Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and
• Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and
main circuit for the model installed.
• The caution items stated here must be followed because these important contents are related to safety. The meaning of each
indication used is as below.
Incorrect installation or servicing due to ignoring of the instruction will cause harm or damage, and the seriousness is classified
by the following indications.
Incorrect installation or servicing due to ignoring of the instruction will cause harm or damage, and the seriousness is classified
by the following indications.
The items to be followed are classified by the symbols:
• Carry out test running to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, care and
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to properties.
This symbol denotes item that is PROHIBITED from doing.
1.
Engage dealer or specialist for installation and servicing. If installation or servicing done by the user is defective, it will cause water leakage,
electrical shock or fire.
electrical shock or fire.
2.
Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock or fire.
3.
Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage,
fire or electrical shock.
fire or electrical shock.
4.
Install at a strong and firm location which is able to withstand the set's weight. If the strength is not enough or installation is not properly
done, the set will drop and cause injury.
done, the set will drop and cause injury.
5.
For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single
outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
6.
Use the specified cable and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no external force will
be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
7.
Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause
heat-up at connection point of terminal, fire or electrical shock.
heat-up at connection point of terminal, fire or electrical shock.
3
8.
When connecting the piping, do not allow air or any substances other than the specified refrigerant to enter the refrigeration
cycle. Otherwise, this may lower the capacity, cause abnormally high pressure in the refrigeration cycle, and possibly result in
explosion and injury.
cycle. Otherwise, this may lower the capacity, cause abnormally high pressure in the refrigeration cycle, and possibly result in
explosion and injury.
9.
Thickness of copper pipes used must be more than 0.6 mm. Never use copper pipes thinner than 0.6 mm.
10. It is desirable that the amount of residual oil is less than 40 mg/10 m.
11. Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with other
electrical appliances. Otherwise, it will cause fire or electrical shock.
1.
The equipment must be earthed. It may cause electrical shock if grounding is not perfect.
2.
Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding
of the unit, it may cause fire.
of the unit, it may cause fire.
3.
Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the
furniture.
furniture.
4.
Pb free solder has a higher melting point than standard solder; typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high
temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
Pb free solder will tend to splash when heated too high (about 1100°F/600°C).
temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
Pb free solder will tend to splash when heated too high (about 1100°F/600°C).
1.
Selection of the installation location. Select an installation location which is rigid and strong enough to support or hold the unit, and select a
location for easy maintenance.
location for easy maintenance.
2.
Power supply connection to the conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following
methods. Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency.
In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
methods. Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency.
In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
1. Power supply connection to the receptacle using a power plug. Use an approved power plug with earth pin for the connection to the
socket.
2. Power supply connection to a circuit breaker for the permanent connection. Use an approved circuit breaker for the permanent
connection. It must be a double pole switch with a minimum 3.5 mm contact gap.
3.
Do not release refrigerant during piping work for installation, servicing reinstallation and during repairing a refrigeration parts. Take care of
the liquid refrigerant, it may cause frostbite.
the liquid refrigerant, it may cause frostbite.
4.
Installation work. It may need two people to carry out the installation work.
5.
Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
4
2 Specifications
2.1.
CS-E18GKDW CU-E18GKD
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT
Performance Test Condition
JIS
C
O
O
O
O
L
I
N
G
G
Capacity
kW
5.30 (0.90 ~ 6.00)
BTU/h
18100 (3070 ~ 20500)
kCal/h
4560 (770 ~ 5160)
EER
W/W
3.21 (4.19 ~ 2.93)
BTU/hW
11.0 (14.3 ~ 10.0)
Noise Level
dB (A)
High 44, Low 37
High 47
Power level dB
57
60
H
E
A
E
A
T
I
N
G
G
Capacity
kW
6.60 (0.90 ~ 8.00)
BTU/h
22500 (3070 ~ 27300)
kCal/h
5680 (770 ~ 6880)
COP
W/W
3.69 (3.67 ~ 3.02)
BTU/hW
12.6 (12.5 ~ 10.3)
Noise Level
dB (A)
High 44, Low 37
High 47
Power level dB
57
60
Moisture Removal
l/h
2.9
pt/h
6.1
Air Volume
Lo
m
3
/min (ft
3
/min)
Cooling; 12.3 (430)
—
Heating; 13.0 (460)
Me
m
3
/min (ft
3
/min)
Cooling; 13.9 (490)
—
Heating; 14.6 (520)
Hi
m
3
/min (ft
3
/min)
Cooling; 15.2 (540)
Cooling; 40.0 (1410)
Heating; 16.7 (590)
Heating; 40.0 (1410)
Refrigeration Control Device
—
Expansion Valve
Refrigeration Oil
cm
3
—
RB68A or Freol Alpha68M (400)
Refrigerant (R410A)
g (oz)
—
1.18k (41.7)
Dimension
Height
mm (inch)
275 (10-13/16)
750 (29-17/32)
Width
mm (inch)
998 (39-9/32)
875 (34-7/16)
Depth
mm (inch)
230 (9-1/16)
345 (13-19/32)
Net Weight
kg (lbs)
10 (22)
48 (106)
Pipe Diameter
Gas
mm (inch)
12.7 (1/2)
Liquid
mm (inch)
6.35 (1/4)
Standard Length
m (ft)
5.0 (16.4)
Pipe Length Range
m (ft)
3 (9.8) ~ 20 (65.6)
Height Difference
m (ft)
15 (49.2)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
Refrigeration Charge Less
m (ft)
10 (32.8)
Drain Hose
Inner Diameter
mm
12
—
Length
mm
650
—
Compressor
Type
—
Hermetic Motor
Motor Type
—
Brushless (4-pole)
Rated Output
W
—
900
Fan
Type
Cross-Flow Fan
Propeller Fan
Material
ASHT-18
PP
Motor Type
Transistor (8-pole)
Transistor (8-pole)
Output Power
W
30
40
Fan Speed
Lo (Cool/Heat)
rpm
1170 / 1240
—
Me (Cool/Heat)
rpm
1330 / 1395
—
Hi (Cool/Heat)
rpm
1450 / 1580
660 / 640