CS-C7JKD, CS-C9JKD, CS-C12JKD, CU-C7JKD, CU-C9JKD, CU-C12JKD - Panasonic Air Conditioner Service Manual (repair manual). Page 57

Read Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD Service Manual online

57 
x  Piping Length Characteristic 
o  Outdoor temperature:  35°C (DBT), 24°C (WBT) 
o  Operation condition: 
High fan speed 
o Piping 
length:  
7.5m 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
4.00
3.90
3.80
3.70
3.60
C
u
rr
ent (A
)
Piping Length (m)
0.540
0.535
0.530
0.525
0.520
Gas S
ide
P
ipi
ng P
res
ure (Mpa)
Piping Length (m)
2.70
2.65
2.60
2.55
2.50
220V
240V
C
apac
it
y (kW
)
Piping Length (m)
15.7
15.6
15.5
15.4
15.3
Outdoor A
ir (ºC
)
Piping Length (m)
3
4
5
6
7
8
9
10
3
4
5
6
7
8
9
10
3
4
5
6
7
8
9
10
3
4
5
6
7
8
9
10
220V
240V
Page of 63