CS-C7JKD, CS-C9JKD, CS-C12JKD, CU-C7JKD, CU-C9JKD, CU-C12JKD - Panasonic Air Conditioner Service Manual (repair manual)

cs-c7jkd, cs-c9jkd, cs-c12jkd, cu-c7jkd, cu-c9jkd, cu-c12jkd service manual
Model
CS-C7JKD CS-C9JKD CS-C12JKD CU-C7JKD CU-C9JKD CU-C12JKD
Pages
63
Size
3.9 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-c7jkd-cs-c9jkd-cs-c12jkd-cu-c7jkd-cu-c9jkd-cu-c.pdf
Date

Read Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD Service Manual online

 
Order No: PHAAM0810022C8 
 
 
 
Indoor Unit 
Outdoor Unit 
 
CS-C7JKD 
CS-C9JKD 
CS-C12JKD 
CU-C7JKD 
CU-C9JKD 
CU-C12JKD 
 
 
 
 
 
TABLE OF CONTENTS 
1.
Safety Precautions.............................................3
2.
Specification .......................................................5
3.
Features ............................................................11
4.
Location of Controls and Components .........12
4.1
Indoor Unit..................................................12
4.2
Outdoor Unit ...............................................12
4.3
Remote Control ..........................................12
5.
Dimensions .......................................................13
5.1
Indoor Unit..................................................13
5.2
Outdoor Unit ...............................................14
6.
Refrigeration Cycle Diagram...........................15
7.
Block Diagram ..................................................16
8.
Wiring Connection Diagram............................17
9.
Electronic Circuit Diagram ..............................18
10. Printed Circuit Board .......................................19
10.1
Indoor Unit..................................................19
11. Installation Instruction.....................................21
11.1
Select the Best Location ............................21
11.2
Indoor Unit..................................................22
11.3
Outdoor Unit ...............................................25
12. Operation Control.............................................28
12.1
Cooling Operation ......................................28
12.2
Soft Dry Operation......................................29
12.3
Automatic Operation ..................................30
12.4
Indoor Fan Speed Control..........................31
12.5
Outdoor Fan Speed Control .......................32
12.6
Vertical Airflow Direction Control................33
12.7
Horizontal Airflow Direction Control ...........33
12.8
Powerful Operation.....................................33
12.9
Quiet Operation ..........................................34
12.10 Timer Control..............................................35
12.11 Random Auto Restart Control ....................35
12.12 Remote Control Signal Receiving Sound...35
12.13 Patrol Operation .........................................36
12.14 e-ion operation ...........................................39
13. Protection Control............................................42
13.1
Restart Control (Time Delay Safety Control)
 42
13.2
7 Minutes Time Save Control.....................42
13.3
60 Seconds Forced Operation ...................42
13.4
Starting Current Control .............................42
13.5
Freeze Prevention Control .........................43
 
 
This service information is designed for experienced repair technicians only and is not designed for use by the general public. 
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. 
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service 
or repair the products dealt with in this service information by anyone else could result in serious injury or death. 
WARNING
13.6
Compressor Reverse Rotation Protection 
Control ...................................................................43
13.7
Dew Prevention Control .............................44
14. Servicing Mode .................................................45
14.1
Auto OFF/ON Button ..................................45
14.2
Remote Control Button ...............................46
15. Troubleshooting Guide....................................47
15.1
Refrigeration cycle system .........................47
16. Disassembly and Assembly Instructions ......49
16.1
Indoor Electronic Controllers, Cross Flow 
Fan and Indoor Fan Motor Removal Procedures..49
17. Technical Data ..................................................53
17.1
Thermostat Characteristics ........................53
17.2
Operation Characteristics ...........................54
18. Exploded View and Replacement Pars List...60
18.1
Indoor Unit ..................................................60
18.2
Outdoor Unit ...............................................62
 
CAUTION 
WARNING 
WARNING 
1. Safety Precautions 
x  Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. 
x  Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the 
power plug and main circuit for the model installed. 
x  The caution items stated here must be followed because these important contents are related to safety. The 
meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction 
will cause harm or damage, and the seriousness is classified by the following indications. 
 
 
This indication shows the possibility of causing death or serious injury. 
 
This indication shows the possibility of causing injury or damage to properties. 
 
x  The items to be followed are classified by the symbols: 
 
 
x  Carry out test running to confirm that no abnormality occurs after the servicing. Then, explain to user the 
operation, care and maintenance as stated in instructions. Please remind the customer to keep the operating 
instructions for future reference. 
 
 
1.   Do not modify the machine, part, material during repairing service. 
2.   If wiring unit is supplied as repairing part, do not repair or connect the wire even only partial wire break. Exchange the whole wiring unit. 
3.   Do not wrench the fasten terminal. Pull it out or insert it straightly. 
4.   Engage dealer or specialist for installation and servicing. If installation of servicing done by the user is defective, it will cause water leakage, 
      electrical shock or fire. 
5.   Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electric shock or fire. 
6.   Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage, fire 
      or electrical shock. 
7.   Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done,
      the set will drop and cause injury. 
8.   For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single outlet
      must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 
9.   This equipment is strongly recommended to install with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it 
      may cause electrical shock and fire in case equipment breakdown or insulation breakdown. 
10. Use the specified indoor/outdoor connection cable [1.5 mm
2
 (1.0 ~ 1.5HP) or 2.5 mm
2
 (2.0 ~ 2.5HP)], and connect tightly for indoor/outdoor  
      connection. Connect tightly and clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it 
      will cause heat-up or fire at the connection. 
11. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause 
      heat-up or fire at the connection point of terminal, fire or electrical shock. 
12. When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into refrigeration cycle.  
      Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosive and injury. 
13. Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise building, child may  
      climb up to outdoor unit and cross over the handrail and causing accident. 
14. This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning rod and  
      telephone. Otherwise, it may cause electric shock in case equipment breakdown or insulation breakdown. 
15. Keep away from small children, the thin film may cling to nose and mouth and prevent breathing. 
16. Do not damage or use unspecified power supply cord. Otherwise it will cause fire or electric shock.  
17. Do not modify the length of the power supply cord or use extension cord, and do not share the single outlet with other electric 
      appliances. Otherwise, it will cause fire or electric shock. 
18. During pump down operation, stop the compressor before remove the refrigeration piping. When remove piping while valve at open  
      condition, burst may occur and cause injury. 
19. During installation, before run the compressor, confirm the refrigerant pipes are fixed. Operation of compressor without fixing the piping, 
      setting the valves at open condition, a burst may occur and cause injury. 
 
This symbol denotes item that is PROHIBITED from doing. 
CAUTION 
WARNING 
 
 
20. After completion of installation or service, confirm there is no leakage or refrigerant gas. It may generate toxic gas when the refrigerant  
      contacts with fire. 
21. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when refrigerant contacts with fire. 
22. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury. 
23. Must not use other parts except original parts described in catalog and manual. 
 
 
1.   Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the  
      unit, it may cause fire. 
2.   Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage  
      the furniture. 
3.   Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare  
      may break and cause refrigerant gas leakage. 
4.   Do not touch outdoor unit air inlet and aluminium fin. It may cause injury. 
5.   Select an installation location which is easy for maintenance. 
6.   Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F – 70°F (30°C – 40°C) higher. Please use 
      a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C). 
      Pb free solder will tend to splash when heated too high (about 1100°F / 600°C). 
7.   Power supply connection to the air conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following 
      methods. 
      Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries, 
      permanent connection of this room air conditioner to the power supply is prohibited. 
      i. Power supply connection to the receptacle using a power plug. 
         Use an approved 15/16A (1.0~1.5HP) or 16A (2.0HP) or 20A (2.5HP) power 
         plug with earth pin for the connection to the socket. 
      ii. Power supply connection to a circuit breaker for the permanent component. 
          Use an approved 15/16A (1.0~1.5HP) or 20A (2.5HP) circuit  
          breaker for the permanent connection. It must be a double pole switch with a minimum 3.0 mm contact gap. 
8.   Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. 
      Take care of the liquid refrigerant, it may cause frostbite 
9.   Installation or servicing work: It may need two people to carry out the installation or servicing work. 
10. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc. 
11. Do not sit or step on the unit, you may fall down accidentally. 
12. Do not touch the sharp aluminium fin, sharp parts may cause injury. 
 
 
 
Page of 63
Display

Download Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD Service Manual (Repair Manual)

Here you can read online and download Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD Service Manual in PDF. CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.