Cooling or Soft Dry Operation
When you press the SLEEP Mode, the following movement will
start to avoid overcooling.
start to avoid overcooling.
•
When
the
room
temperature
reaches
the
setting
temperature or after 1 hour of operation, sleep shift
operation starts and the airflow volume will automatically
change to low.
operation starts and the airflow volume will automatically
change to low.
•
The setting temperature will be risen by 0.5°C at the start of
operation and by 0.5°C one hour later.
operation and by 0.5°C one hour later.
•
The operation will stop after 8 hours.
8.5. Sleep Mode Auto Operation
8.6. Powerful Mode Operation
•
Purpose of this operation is to obtain the setting temperature quickly.
•
When the Powerful Mode is set, the set temperature will be automatically decreased 3°C against the present setting
temperature.
temperature.
This operation automatically will be running under Super High Fan speed.
•
Vertical Airflow Direction:-
- In “Manual” setting, the vane will automatically swing down 10° lower than previous setting.
- In “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.
•
Powerful Mode will operate for 15 minutes only.
•
Powerful Mode will stop if:-
- Powerful mode button is pressed again.
- Stopped by ON / OFF switch.
- Timer OFF activates.
- Economy mode button is pressed.
- Sleep mode is pressed.
- Operation mode button is changed.
8.7. Economy Mode Operation
•
Purpose of this operation is to save or reduced electrical power consumption of the room air conditioner.
•
When the Economy Mode is set, the set temperature will be automatically increased 0.5°C against the preset setting
temperature. This operation automatically will be running under Random Fan speed.
temperature. This operation automatically will be running under Random Fan speed.
(Refer operation details no. 8.9)
•
Vertical Airflow Direction:-
In “Manual” or “Auto” setting, the vane will automatically change to Auto Air Swing.
•
Economy Mode will stop if:-
- Economy Mode button is pressed again.
- Stopped by ON / OFF switch.
- Timer OFF activates.
- Powerful mode button is pressed.
- Auto or Manual air swing button is pressed.
- Fan Speed control button is pressed.
- Sleep Mode button is pressed ON.
- Operation Mode is changed.
22
S-C75KE CU-C75KE / CS-C95KE CU-C95KE / CS-C125KE CU-C125KE