CS-C75KE, CS-C95KE, CS-C125KE, CU-C75KE, CU-C95KE, CU-C125KE - Panasonic Air Conditioner Service Manual (repair manual)

cs-c75ke, cs-c95ke, cs-c125ke, cu-c75ke, cu-c95ke, cu-c125ke service manual
Model
CS-C75KE CS-C95KE CS-C125KE CU-C75KE CU-C95KE CU-C125KE
Pages
88
Size
8.86 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / SPLIT TYPE
File
cs-c75ke-cs-c95ke-cs-c125ke-cu-c75ke-cu-c95ke-cu-c.pdf
Date

Read Panasonic CS-C75KE / CS-C95KE / CS-C125KE / CU-C75KE / CU-C95KE / CU-C125KE Service Manual online

 1 
Features 
2
 2 
Functions 
3
 3 
Product Specifications 
6
 4 
Dimensions 
12
 5 
Refrigeration Cycle Diagram 
14
 6 
Block Diagram 
15
 7 
Wiring Diagram 
16
 8 
Operation Details 
17
 9 
Operating Instructions 
25
 10 Installation Instructions 
49
 11 2-way, 3-way Valve 
58
CS-C75KE CU-C75KE
CS-C95KE CU-C95KE
CS-C125KE CU-C125KE
 12 Servicing Information 
65
 13 Troubleshooting Guide 
69
 14 Technical Data 
71
 15 Exploded View 
74
 16 Replacement Parts List 
75
 17 Exploded View 
76
 18 Replacement Parts List 
77
 19 Exploded View 
78
 20 Replacement Parts List 
79
 21 Electronic Parts List 
80
 22 Electronic Circuit Diagram 
81
Room Air Conditioner
CONTENTS
 Page 
Page
Order No: MAC0010048C2
  • 
High Efficiency
  • 
Compact Design
  • 
Comfort Environment
  − 
8 hours of sleep mode operation
  − 
Air filter with function to reduce dust and smoke
  − 
Wider range of horizontal discharge air
  • 
Auto Restart
  − 
Random auto restart after power failure for safety restart
operation
  • 
Removable and Washable Front Panel
  • 
Remote Control Self-illuminating Button
  • 
Catechin Air Purifying Filter
  − 
Trap dust, tabacco smoke and tiny particles
  − 
Prevent the growth of bacteria and viruses trapped
  • 
Deodorizing Air Purifying Filter
  − 
Remove unpleasant odors from the air
  • 
Quality Improvement
  − 
Gas leakage protection
  − 
Prevent compressor reverse cycle
  − 
2-stage OLP to protect compressor
  − 
Noise prevention during soft dry operation.
  • 
Service Improvement
  − 
Easy fan motor replacement procedure
  • 
Operation Improvement
  − 
Economy mode to reduce electrical power consumption
  − 
Powerful mode to reach the desired room temperature
quickly
  • 
Long Installation Piping
  − 
CS/CU-C75KE, CS/CU-C95KE, long piping up to 10
meter
  − 
CS/CU-C125KE, long piping up to 15 meter
1 Features
2
S-C75KE CU-C75KE / CS-C95KE CU-C95KE / CS-C125KE CU-C125KE
2 Functions
Remote Control
Operation OFF / ON
OFF / ON 
I
Room Temperature Setting
TEMP.
Operation Mode Selection
AUTO
Automatic Operation Mode
COOL
Cooling Operation Mode
DRY
Soft Dry Operation Mode
FAN
Air Circulation Mode
MODE
TIMER
Time / Timer Setting
• Hours and minutes setting.
Clock Setting
• Current time setting.
Sleep Mode Operation OFF / ON
SLEEP
Indoor Fan Speed Selection
FAN SPEED
h j k
Low Speed
l
h j k
Medium Speed
lll
h j k
High Speed
lllll
AUTOFAN
Automatic Fan Speed
Airflow Direction Control
• 24-hour, OFF / ON Real Timer Setting.
ON-TIMER
OFF-TIMER
Timer Operation Selection
SET
CANCEL
Timer Operation Set / Cancel
• ON Timer and OFF Timer setting and
cancellation.
CLOCK
AIR SWING
AUTO
Automatic Airflow Direction
Control
MANUAL
Airflow Direction Manual
Control
Powerful Mode Operation OFF/ON
POWERFUL
Economy Mode Operation OFF/ON
ECONOMY
• Temperature Setting (16°C to 30°C)
• Automatic Operation
2°C higher than standard
Standard
2°C lower than standard
HI
a
a
a
Lo
Self illuminating
button
3
CS-C75KE CU-C75KE / CS-C95KE CU-C95KE / CS-C125KE CU-C125KE
Indoor Unit
Random Auto Restart Control
• Operation is restarted randomly after
power failure at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Sleep Mode Auto Control
• Indoor Fan operates at Low speed.
• Operation stops after 8 hours.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
Cooling : Fan rotates at Hi and Me
speed. Deodorizing control
is available.
Soft Dry: Fan rotates at Lo speed.
Deodorizing control
is available.
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal airflow.
Airflow Direction Control
Automatic Operation Button
• Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
• Press continuously for 5s or < 10s  to
operate Test Run/Pump down. “Beep”
sound will be heard at the 5th second.
(Used when test running or servicing.)
• Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. “Beep, beep” sound will
be heard at the 10th second.
AUTO
OFF / ON
Operation Indication Lamps (LED)
POWER
 (Green) ........ Lights up in operation,
blinks in Automatic
Operation Mode
judging.
SLEEP
 (Orange) ........ Lights up in Sleep
Mode Operation.
TIMER
 (Orange) ....... Lights up in Timer
Setting.
POWERFUL
 (Orange) .. Lights up in Powerful
Mode Operation.
ECONOMY
 (Green) ..... Lights up in Economy
Mode Operation.
Operation Mode
• Cooling, Soft Dry, Air Circulation and
Automatic Mode.
Powerful Operation
• Reaches the desired room temperature
quickly.
Time Delay Safety Control
• Restarting is inhibited for appro. 3
minutes.
Starting Current Control
Economy Operation
• To reduce electrical power consumption.
7 Minutes Time Save Control
• Cooling Operation only.
4
S-C75KE CU-C75KE / CS-C95KE CU-C95KE / CS-C125KE CU-C125KE
Page of 88
Display

Download Panasonic CS-C75KE / CS-C95KE / CS-C125KE / CU-C75KE / CU-C95KE / CU-C125KE Service Manual (Repair Manual)

Here you can read online and download Panasonic CS-C75KE / CS-C95KE / CS-C125KE / CU-C75KE / CU-C95KE / CU-C125KE Service Manual in PDF. CS-C75KE / CS-C95KE / CS-C125KE / CU-C75KE / CU-C95KE / CU-C125KE service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic CS-C75KE / CS-C95KE / CS-C125KE / CU-C75KE / CU-C95KE / CU-C125KE Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.